Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 13 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
11 Fault
conditions
11.1
No shock hazard under fault condition ……………:
No electric shock hazard under
fault conditions.
fault conditions.
P
11.2
Heating under fault condition ………………….:
(see appended table 11.2)
P
Flames extinguish within 10 seconds ..................:
No flames
P
No hazard from softening solder ……………...:
No softening of solder
P
Soldered terminations not used as protective
mechanism ………………………………..:
mechanism ………………………………..:
No soldered terminations
P
11.2.1
Measurement of temperature rises ……..:
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts ……...:
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation ………:
providing electrical insulation ………:
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min ...:
exceeding the limits of table 3 by max. 100 K for
max. 5 min ...:
No exceeding the limits of
Table 3.
Table 3.
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² :
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² :
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min …………….:
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min …………….:
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted …...:
printed circuit boards are interrupted …...:
No conductors are
interrupted/peeled/loosened
during fault conditions
interrupted/peeled/loosened
during fault conditions
P
Class I protective earthing maintained ………….:
Class II equipment
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier ….:
mechanical barrier ….:
(see appended table 11.2)
P
11.2.5
Temperature rise of windings ………………:
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5 ………………:
11.2.1 to 11.2.5 ………………:
No excessive temperature
observed/measured on
other parts.
(see appended table 11.2)
observed/measured on
other parts.
(see appended table 11.2)
P
Click on the first or last page to see other AVR 360 service manuals if exist.