AVR 360 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 20

Read Harman Kardon AVR 360 EMC - CB Certificate online

 
 
- Page 16 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition …: 
Capacitors C904 certified 
according to 
IEC 60384-14, 2
nd
 edition, 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ………………: 
No such capacitors 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better ……: 
Several E. cap. Vol. >1750mm
3
,
but metal cases. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better ………………………: 
Several E. cap. Vol. >1750mm
3
,
but metal cases. 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ………………………………………….: 
 N/A 
14.3 
Inductors and windings  
 P 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 …………….: 
Transformers evaluated  
according to 14.3.3, 14.3.4 
and 14.3.5 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type …………….: 
Adequate marking applied. 
Mfr, ID and type no. 
 
Transformers and inductors separately approved ….:
No 
N/A 
14.3.2 General 
……………………………: 
Isolating transformers 
 
Insulation material complies with clause 20.1.4 …: 
Considered.  The insulation 
material of isolating transf. 
complies with flammability 
category of Table 21. 
14.3.3 
Constructional requirements  
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 ……………………………..: 
(see appended table 13) 
14.3.3.2 Transformers 
meet 
the constructional requirements:
(see appended table 14.3.3) 
14.3.4 
Separation between windings 
 
 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) …………………...: 
Double or reinforced  
insulation between primary 
and secondary windings 
according to clause 8.8. 
(see appended table 14.3.3) 
 
Coil formers and partition walls > 0,4 mm ……...: 
Main and Sub transf. bobbin 
fulfils the requirement of 
reinforced insulation; bobbin 
thickness > 0,4 mm. 
Page of 65