Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 16 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition …:
Capacitors C904 certified
according to
IEC 60384-14, 2
according to
IEC 60384-14, 2
nd
edition,
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ………………:
connected to the mains: tests for X2 ………………:
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ………………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ………………………:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ………………………………………….:
metal ………………………………………….:
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4 …………….:
(as relevant) and clause 20.1.4 …………….:
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type …………….:
manufacturer's name and type …………….:
Adequate marking applied.
Mfr, ID and type no.
Mfr, ID and type no.
P
Transformers and inductors separately approved ….:
No
N/A
14.3.2 General
……………………………:
Isolating transformers
P
Insulation material complies with clause 20.1.4 …:
Considered. The insulation
material of isolating transf.
complies with flammability
category of Table 21.
material of isolating transf.
complies with flammability
category of Table 21.
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13 ……………………………..:
clause 13 ……………………………..:
(see appended table 13)
P
14.3.3.2 Transformers
meet
the constructional requirements:
(see appended table 14.3.3)
P
14.3.4
Separation between windings
P
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm ……...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P
Click on the first or last page to see other AVR 360 service manuals if exist.