Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 8 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings …….:
switch location, accessibility and markings …….:
Plug is regarded as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected
equipment ...:
equipment ...:
Not permanent connected
equipment
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains …………...…:
disconnection from the mains …………...…:
Information provided in user
manual.
manual.
P
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h) ………….:
No ionizing radiation
N/A
Ionizing radiation under fault condition …………….:
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ….:
No laser radiation
N/A
Emission limits under fault conditions …………..:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated .:
fuse links and other protective devices defeated .:
No fuse links operate during
normal operating operation.
(see appended table)
normal operating operation.
(see appended table)
P
7.1.1
Temperature rise of accessible parts ………………..:
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation:
insulation:
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier …………………………………..:
mechanical barrier …………………………………..:
(see appended table 7.1)
P
7.1.4
Temperature rise of windings ……………………:
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C :
See appended table 7.2 for
AC connector (wafer) CN91
and CN92.
AC connector (wafer) CN91
and CN92.
P
Click on the first or last page to see other AVR 360 service manuals if exist.