Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 7 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
5.2
Earth terminal ………………………..:
Class II apparatus
N/A
Hazardous live terminals ………………:
No hazardous live terminals.
The output signal will rise to
37Vp at maximum out power
if the speaker load is
disconnected in the speaker
terminal, No hazard.
The output signal will rise to
37Vp at maximum out power
if the speaker load is
disconnected in the speaker
terminal, No hazard.
P
Supply output terminals (other than mains) ……..:
“W” and “A” with rated supply
voltage/frequency marked
closed to the socket-outlet;
SWITCHED (50W 0.5A MAX)
voltage/frequency marked
closed to the socket-outlet;
SWITCHED (50W 0.5A MAX)
P
5.3
Use of triangle with exclamation mark …….:
Correct symbol applied:
- In rear side in connection
with CAUTION of opening,
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
- In rear side in connection
with CAUTION of opening,
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
P
5.4
Instructions for use ……………………….:
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc. ……….:
dripping or splashing. Warning concerning objects
filled with liquid, etc. ……….:
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring:
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery …..:
No lithium battery in the
equipment.
equipment.
N/A
d) Class I earth connection warning ………….:
Class II equipment
N/A
e) Instructions for multimedia system connection :
Instructions for multimedia
system connection provided in
user manual.
system connection provided in
user manual.
P
f) Special stability warning for attachment of the
apparatus to the flor/wall ………………………:
apparatus to the flor/wall ………………………:
No such equipment
N/A
g) Warning: battery exposure to heat ……………..:
No battery
N/A
h) Warning: protective film on CRT face ………….:
No CRT
N/A
Click on the first or last page to see other AVR 360 service manuals if exist.