Read Sony KV-SW213M81 Service Manual online
– 13 –
KV-SW213M81
RM-GA002
2-13. HV Lead Assy dressing
2-14. AC Power Cord Dressing
180 ± 5 mm
HV Holder Combi
HV Holder Combi
Purse Lock Ø9
HV Holder Combi
Dress HV Holder
Combi with Purse
Lock Ø9 as shown
Combi with Purse
Lock Ø9 as shown
Fix the bigger diameter hook of HV
Holder Combi on the right side of
black tape & at horizontal bending
of DGC, then use purse lock Ø9 to
secure HV Holder Combi to DGC
Holder Combi on the right side of
black tape & at horizontal bending
of DGC, then use purse lock Ø9 to
secure HV Holder Combi to DGC
SAFETY OPERATION
45º
B
A
A
A
C
DGC
Purse Lock Ø9
PWB Bracket hook
Dress AC Power Cord at PWB Bracket hook as shown.
Terminal Bracket
AC Cord Holder
AC Power Cord
Dress AC Cord Holder at the terminal bracket.
DGC
Conn
outlet
Conn
outlet
Black tape
Place purse lock Ø9 after the
exit of DGC conn from DGC
exit of DGC conn from DGC
TVSR (Clause 9.4.7):
A) Spacing between HV cable and
conductive part's surface --1mm/kV
or more
B) Spacing between edge of anode
cap and conductive parts -->
0.5mm/kV or more
C) Spacing between HV cable &
enclosure with ventilation (i.e. Rear
Cover side) --> 10mm or more
A) Spacing between HV cable and
conductive part's surface --1mm/kV
or more
B) Spacing between edge of anode
cap and conductive parts -->
0.5mm/kV or more
C) Spacing between HV cable &
enclosure with ventilation (i.e. Rear
Cover side) --> 10mm or more
CAUTION:
Keep HV cable facing inwards DY to keep HV cable away from
ventilation side of rear cover --> 10mm or more.
Ensure TVSR 1mm/kV is kept from HV cable to DY & other
conductive parts
Keep HV cable facing inwards DY to keep HV cable away from
ventilation side of rear cover --> 10mm or more.
Ensure TVSR 1mm/kV is kept from HV cable to DY & other
conductive parts
Click on the first or last page to see other KV-SW213M81 service manuals if exist.