– 11 –
KV-SW213M81
   RM-GA002
2-9.  Top Switch wire dressing
2-10.  DY Connector Dressing
DY Connector
Conn Assy, 5P (200V)
Earth Assy, Coating
1) DY Connector
goes underneath of
Earth Assy, Coating
and Connector Assy,
5P (200V) wire.
2) DY Connector goes above
Connector Assy, 5P (200V) wire.
Purse Lock Ø5
Black tape
Top switch wire
under DGC & left
of black tape
Top switch
wire under
DGC & right
of black tape
Ensure Top Switch wire
is dressed around AC
Power Cord --> keep
away from heatsink
CAUTION:
1. Do not overpull the wires during dressing --> avoid disconnection of wires.
2. Make sure wires are kept away from sharp edges, heatsinks & other
  high-temperature parts.
1
2
3
3) Dress DY
Connector and
Connector Assy, 5P
(200V) wire with Purse
Lock Ø5.
Use heatsink height to
estimate purse lock location
Purse Lock Ø5
Dress wires away
from FBT area
Conn Assy, 5P
(200V)
DY Connector
CAUTION:
1. Do not overpull the wires during dressing
  --> avoid disconnection of wires.
2. Make sure wires are kept away from
  sharp edges, heatsinks & other
  high-temperature parts.
TVSR (Clause 9.4.7):
All wires must be kept away from FBT
area by a distance of 10mm or more.
Make sure DY Connector is on
the right side of Earth Assy, Coating.
Page of 64
Display

Click on the first or last page to see other KV-SW213M81 service manuals if exist.