KV-SW213M81 - Sony TV Service Manual (repair manual). Page 13

Read Sony KV-SW213M81 Service Manual online

– 12 –
KV-SW213M81
   RM-GA002
2-11.  Lead Assy, G2 and Lead Assy, Focus dressing
2-12.  Conn Assy, 7P, Connector Assy, 3P, Lead Assy, Earth & Rotational Coil Conn dressing
Purse Lock Ø5
Use this as a
reference to
dress ECA,
Lead Assy,
Focus & G2
 
Lead Assy, Focus
Conn. Assy, 5P (200V)
Earth Assy, Coating
Lead
Assy,
G2
Purse Lock Ø5
HV Cable
Keep Lead Assy,
G2 away from HV
Cable 
(as least 1mm/kv)
Keep Lead Assy,
G2 away from
Heat Sink.
Lead Assy, G2
Lead Assy,
G2
Lead Assy,
Focus
Earth Assy,
Coating
Purse Lock Ø5
3D models 
Purse Lock Ø9
Lead Assy, Earth
Conn Assy, 7P
Keep wires away
from heat sinks
UL Wire (1-923-000-81)
Conn Assy, 3P 
Rotational Coil Conn 
Non 3D models
Purse Lock Ø5
Conn Assy, 7P
Rotational Coil Conn
Lead Assy, Earth
UL Wire (1-923-000-81)
Lead Assy, Earth
Connector Assy, 7P
 UL Wire
Rotational Coil Conn.
Conn Assy, 3P
DY
90
o
Wire from
Rotation Coil
Connector Assy, 7P
Lead Assy, Earth
  UL Wire
Lead Assy, Focus & Lead Assy, G2 is pulled straight up
from FBT to Earth Assy, Coating & dressed together with
purse lock Ø5
TVSR (Clause 9.4.7) :
- Keep HV cables away from
  conductive parts 1mm/KV or more
CAUTION:
1. Do not overpull the wires during dressing -->
avoid disconnection of wires.
2. Make sure wires are kept away from sharp
edges, heatsinks & other high-temperature parts.
Keep wires away
from heat sinks
UL Tape
UL Tape
Purse Lock Ø9
Purse Lock Ø5
Rotational Coil Conn
CAUTION:
1. Do not overpull the wires during dressing --> avoid
disconnection of wires.
2. Make sure wires are kept away from
sharp edges, heatsinks & other high-temperature parts.
Rotation Coil
Page of 64