MHS-TS55 (serv.man2) - Sony Movie Service Manual (repair manual). Page 5

Read Sony MHS-TS55 (serv.man2) Service Manual online

MHS-TS55_ADJ
5-5
5-3-4. WB/AGC Adjustment
The WB/AGC (White Balance/Analog Gain Control) adjustment order 
is as follows.
Note:
Perform this adjustment after that performed in 5-3-3.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
 Fig. 
5-3-10
The adjustment is complete.
The adjustment is finished abnormally.
 Fig. 
5-3-11
Malfunction of WB/AGC  
adjustment result
Finished normally.
Finished abnormally.
Confirm the indication
on the screen.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Touch the Left area, Right area, or the Top area, Bottom area on the LCD screen to choose an adjustment item.
Select “WB/AGC (LV10)”, press the
(Shutter) button
, then confirm that each value of “Light Src” is set as “002”,
“P1 R Ratio” is set as “1038”, and “P1 B Ratio” is set as “916”.
“P2 R Ratio” is set as “1332”, and “P2 B Ratio” is set as “703”.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-9)
Touch the Left area, Right area, or the Top area, Bottom area on the LCD screen to choose an adjustment item
.
Select
“WB/AGC (LV10)”, and touch the Center area on the LCD screen.
Select “OK”, and touch the Center area of the LCD screen to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-11)
In this case, confirm the adjusting environment
and readjust.
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-3-10)
Press the
(Shutter) button
to return to
adjustment menu.
The adjustment is finished normally.
 Fig. 
5-3-7
The adjustment is complete.
5-3-3. OB Adjustment
The OB (Optically Black) adjustment order is as follows.
The adjustment is finished abnormally.
 Fig. 
5-3-8
Malfunction of OB 
adjustment result
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Cover camera lens (All black). (Fig. 5-3-6)
Touch the Left area, Right area, or the Top area, Bottom area on the LCD screen to choose an adjustment item.
Select “OB CLBT (BLACK)”, and touch the Center area on the LCD screen.
Select “OK”, and touch the Center area of the LCD screen to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-3-7)
Press the
(Shutter) button to return to
adjustment menu.
Finished normally.
Finished abnormally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-8)
In this case, confirm the adjusting environment
and readjust.
Confirm the indication
on the screen.
Adjustment order
Screen display
Adjustment order
Screen display
Equipments required: Cover camera lens
(All black)
Camera
Black cloth
 Fig. 
5-3-6
Small pattern box
(PTB-1450)
5 mm or less
Black cloth
Camera
Equipments required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
 Fig. 
5-3-9
Page of 8
Display