MHS-TS55_ADJ
5-4
The adjustment is finished abnormally.
 Fig. 
5-3-5
Malfunction of EIS 
adjustment result
5-3. CAMERA SECTION ADJUSTMENTS
5-3-1. Focus Adjustment
The Focus adjustment order is as follows.
Note: 
When using the Flange back adjustment jig, take care of the following points:
•  For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering.
•  Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only.
•  Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination.
1)  Install the Flange back adjustment jig so that the distance between 
it and the front of lens of camera is 10 mm or less.
Note:
Take care not to hit the lens of camera against the lens of Flange back 
adjustment jig.
2)  Make the height of Flange back adjustment jig and the camera equal.
3)  Check that the center of chart meets the center of shot image screen.
Illuminance = 1000 ± 200 lx
Adjustment order
Screen display
The adjustment is finished normally.
 Fig. 
5-3-2
The adjustment is complete.
The adjustment is finished abnormally.
 Fig. 
5-3-3
Malfunction of Focus 
adjustment result
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Flange back adjustment jig. (Fig. 5-3-1)
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-3)
In this case, confirm the adjusting environment
and readjust.
Touch the Left area, Right area, or the Top area, Bottom area on the LCD screen to choose an adjustment item.
Select “FOCUS (Infinity)”, and touch the Center area on the LCD screen.
Select “OK”, and touch the Center area of the LCD screen to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-3-2)
Press the
(Shutter) button to return to
adjustment menu.
Finished normally.
Finished abnormally.
Confirm the indication
on the screen.
5-3-2. EIS Adjustment
The EIS (Electrical Image Stabilizer) adjustment order is as follows.
Note:
Perform this adjustment after that performed in 5-3-1.
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-5)
In this case, confirm the adjusting environment
and readjust.
Touch the Left area, Right area, or the Top area, Bottom area on the LCD screen to choose an adjustment item.
Select “
EIS”, and touch the Center area on the LCD screen.
Select “OK”, and touch the Center area of the LCD screen to start.
*1 If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
*2 When the adjustment starts, put the camera on a stable place such as a table to prevent it from wobbling.
*3 It takes approximately 30 seconds or more on this adjustment.
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-3-4)
Press the
(Shutter) button
to return to
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Touch the Left area, Right area, or the Top area, Bottom area on the LCD screen to choose an adjustment item.
Select “EIS”, press the
(Shutter) button, then confirm that the value of “Gyro” is set as “001”.
The adjustment is finished normally.
 Fig. 
5-3-4
The adjustment is complete.
Adjustment order
Screen display
Flange back adjustment jig
10 mm or less
Camera
Equipments required: Flange back adjustment jig
 Fig. 
5-3-1
Page of 8
Display