SAL70200G2 - Sony Digital Camera Service Manual (repair manual). Page 17

Read Sony SAL70200G2 Service Manual online

2-14
SAL70200G2 (2.8/70-200 G SSM Ⅱ) (70-200mm F2.8 G SSM II)
HELP21
Adhesive bond (B-10): J-6082-612-A
1.  Set the focus to the near position.
2.  Assemble the MF detection brush block in the arrow direction as shown in the figure.
Note:
  Be careful not to bend the leads of brush.
3.  Move the focus ring by 10mm in the infinity direction.
4.  Slide the MF detection brush block and align the screw hole of MF detection brush block with the front holding barrel.
5.  Tighten two screws and apply the adhesive bond (B-10) to the indicated portions of screw heads.
6.  Adjust the position of flexible PWB, aligning the positioning hole of flexible PWB, and solder it.
7.  Route the harness as shown in the figure and solder it.
Assemble the MF detection
brush block in the arrow direction
Soldering
(Harness)
Harness
(Green)
Harness
(Black)
Apply the adhesive
bond (B-10)
Soldering
(Flexible PWB)
Move the focus ring by 10mm
in the infinity direction
Slide the MF detection brush
block and align the screw hole
of MF detection brush block
HELP22
Anti-diffusion agent (A-20): J-6082-611-A
Grease (G-85): J-6082-626-A
1.  Apply the anti-diffusion agent (A-20) to the indicated portion of front holding tube block.
Front Holding Tube Block
Inner side of front holding tube
Cut 
view
Cut 
view
Apply the 
anti-diffusion 
agent (A-20)
Apply the 
anti-diffusion 
agent (A-20) 
Apply the 
anti-diffusion 
agent (A-20) 
Inside
3 mm
Outside
Apply the anti-diffusion agent (A-20)
2.  Apply the grease (G-85) to the indicated portion of front holding tube block
Cut 
view
Cut view
Front Holding Tube Block
Grease (G-85) 
applying area 
Grease (G-85) 
applying area 
Apply the 
grease (G-85)
Apply the 
grease (G-85) 
Inside
Outside
Page of 103