17.
EZ Check
Check
1. Set the camera to the adjsutment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Click “EZ” of the adjustment menu. “Please select menu” appears.
3. Click “CHECK”.
4. “Please select island” appears.  Align the focus frame on the island to be checked.
Use the appropriate chart according to the desired island group. (See table below)
5. Click the island to check. EZ value is displayed. (Fig. 2)
6. Check the value is within the standard, and click “END”.
Note:
 If the reading is beyond the standard, perform “EZ SHIFT”.
Island group
Chart
Measuring point
3rd, 4th, 6th
ISLAND
AF Chart-I (Horizontal)
A (A to D)
5th
ISLAND
AF Chart-I (Vertical)
E (E to H)
1st, 7th
ISLAND
AF Chart-II (Horizontal)
I (I to L)
2nd, 8th
ISLAND
AF Chart-II (Horizontal) *
M (M to P)
* When checking the reading at 2nd island group and 8th island group,
use AF Chart-II upside down.
Set point of focus frame and Island No.
Island (Block) Group Layout
Standard: 0 
± 50
Fig. 1
Fig. 2
Fig. 3
Fig. 4
1 s t
6 t h
5 t h
4 t h
3 r d
7 t h
2 n d
8 t h
1st, 7th
2nd, 8th
3rd, 4th, 5th,
6th
7th (9)
1st (1)
6th (8)
5th (7)
4th (4, 5, 6)
3rd (3)
8th (10)
2nd (2)