MX-M623U, MX-M753U (serv.man10). COMPLETE SERVICE MANUAL - Sharp Copying Equipment Service Manual (repair manual). Page 127

Read Sharp MX-M623U / MX-M753U (serv.man10) Service Manual online

MX-M753N  SIMULATION  6 – 31
NOTE: The set value may be changed for a design change or an individual arrangement. Except for the above cases, however, the set value
must not be changed. If it is changed, a trouble may be occur.
<Code descriptions>
<List of destination groups>
 
43-4
Purpose
Setting
Function (Purpose) Used to set the fusing temperature 2 in
each operation mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
NOTE: The set value may be changed for a design change or an
individual arrangement. Except for the above cases, how-
ever, the set value must not be changed. If it is changed, a
trouble may be occur.
Item
Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
TH_UM set value when ready standby
70 - 240
200
205
200
205
200
205
B
HL_US READY
TH_US set value when ready standby
70 - 240
200
205
200
205
200
205
C
HL_UM PLAIN PAPER BW
Black and white plain paper TH_UM set value
70 - 240
200
205
210
210
D
HL_US PLAIN PAPER BW
Black and white plain paper TH_US set value
70 - 240
200
205
210
210
E
WARMUP FUMON HL_UM T
Fusing motor previous rotation start TH_UM set value
30 - 240
190
50
50
F
WARMUP FUMOFF HL_UM T
Fusing motor previous rotation complete time
0 - 200
5
G
WARM UP END TIME
Warm-up complete time
0 - 200
28
50
28
50
28
50
H
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 240
220
I
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 240
220
J
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 240
210
K
HL_US OHP PAPER
OHP-TH_US set value
70 - 240
210
L
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
165
M
HL_US E-STAR 
Preheating TH_US set value
30 - 200
165
N
PRE-JOB
Resetting from preheating TH_UM set value
30 - 240
180
190
190
O
HL_UM WARMUP_120L
TH_UM set value when warming up of 120
C or less
70 - 240
200
210
215
215
P
HL_US WARMUP_120L
TH_US set value when warming up of 120
C or less
70 - 240
200
210
215
215
Q
LO_WARMUP_TIME 
O - P applying time (Timer from completion of Ready)
0 - 255
5
R
HL_UM WARMUP_120H
TH_UM set value when warming up of 120
C or above
70 - 240
200
210
215
215
S
HL_US WARMUP_120H
TH_US set value when warming up of 120
C or above
70 - 240
200
210
215
215
T
HI_WARMUP_TIME
R - S applying time (Timer from completion of Ready)
0 - 255
5
U
HI_WU_FM_ON_TMP
FM previous rotation start TH_US set value when 
warming up of alpha 
C or above
30 - 240
130
V
HI _WU_END_TIME
Warm-Up complete time when warming up of alpha 
C 
or above
0 - 200
28
50
28
50
28
50
W
HI_WU_JOB_SET_TMP1
Job enable TH UM temperature 1 when warming up of 
alpha 
C or above
70 - 240
190
200
210
210
X
HI_WARMUP_BORDER
U - W applying set value
1 - 119
70
Y
LO_WU_JOB_SET_TMP1
Job enable TH UM temperature 1 when warming up of 
alpha 
C or less
70 - 240
190
200
210
210
Z
JOBEND_FUMON_TIME
After rotation time when Job end
0 - 200
10
AA
HI_WU_JOB_SET_TMP2
Job enable TH UM temperature 2 when warming up of 
alpha 
C or above
70 - 240
195
205
210
210
AB
LO_WU_JOB_SET_TMP2
Job enable TH UM temperature 2 when warming up of 
alpha 
C or less
70 - 240
195
205
210
210
TH_UM
Fusing upper thermistor main
HL_UM
Heater lamp upper main
TH_US
Fusing upper thermistor sub
HL_US
Heater lamp upper sub
SW-A
Setting value when 60 - 89g/m
2
SW-B
Set value when 90 - 105g/m
2
The set value displayed in this simulation differs depending on 
60 - 89g/m
2
 or 90 - 105g/m
2
(Example) When 60 - 89g/m
2
Group
Destination 
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
Page of 127
Display