MX-C310, MX-C311, MX-C312, MX-C380, MX-C381, MX-C400, MX-C401 (serv.man111). L4-16 - FUSING PRESSURE RELEASE TROUBLE CAUSED BY BURRED DETECT ACTUATOR. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp MX-C310 / MX-C311 / MX-C312 / MX-C380 / MX-C381 / MX-C400 / MX-C401 (serv.man111) Technical Bulletin online

 
                                                                                                                                         
CCE 633 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
Location of new Poly Slider 
 
 
4.Action: 
       From mid-December 2008 production. 
 
5.Parts Action: 
Ref. 
No. 
Model 
name 
Version P/G No. 
Current parts 
New parts 
Price
rank
Q'ty Parts 
name 
Effective
time 
Inter- 
change
ability 
Parts code 
Parts code 
MX-C310 
MX-C311 
MX-C380 
MX-C381 
MX-C400 
MX-C401 
DX-C310 
DX-C311 
DX-C380 
DX-C381 
DX-C400 
DX-C401 
ALL 
18-16 
MLEVP1112FCZZ MLEVP1112FCZ2 AQ 
Pressure release 
detect actuator 
2008/12 
Mid 
18- 
--- LX-WZ0017GCZ1 
AC 
Poly 
slider 
20-2 
LPLTP7869FCZZ LPLTP7869FCZ1 AF 
Pressure release 
detect plate N 
<Interchange> 
1. Interchangeable. 
4. Not interchangeable. 
2. Current type can be used in place of new type. 
New type cannot be used in place of current type. 
5. Interchangeable if replaced with same types of  
related parts in use. 
3. Current type cannot be used in place of new type. 
New type can be used in place of current type. 
6. Others. 
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with 
specified ones for maintaining the safety and performance of the set. 
 
Page of 3