MX-C310, MX-C311, MX-C312, MX-C380, MX-C381, MX-C400, MX-C401 (serv.man111). L4-16 - FUSING PRESSURE RELEASE TROUBLE CAUSED BY BURRED DETECT ACTUATOR. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp MX-C310 / MX-C311 / MX-C312 / MX-C380 / MX-C381 / MX-C400 / MX-C401 (serv.man111) Technical Bulletin online

 
                                                                                                                                         
CCE 633 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
Possible configurations of pressure release detect actuator, pressure release detect plate N, 
and poly slider 
 
NEW 
Pressure Release 
Detect Actuator 
(MLEVP1112FCZ2) 
NEW 
Pressure Release 
Detect Plate N 
(LPLTP7869FCZ1) 
Poly Slider 
(LX-WZ0017GCZ1) 
OLD 
Pressure Release 
Detect Actuator 
(MLEVP1112FCZZ) 
--- Impossible 
Impossible 
OLD 
Pressure Release 
Detect Plate N 
(LPLTP7869FCZZ) 
Impossible --- Impossible 
NEW 
Pressure Release 
Detect Actuator 
(MLEVP1112FCZ2) 
--- Possible 
Possible 
NEW 
Pressure Release 
Detect Plate N 
(LPLTP7869FCZ1) 
Possible --- Possible 
 
Pressure Release Detect Actuator 
 
 
How to identify old vs. new parts 
 
 
Pressure Release Detect Plate N 
 
 
Page of 3
Display