Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual online
MX-7000N SIMULATION 7 – 5
26
35
Used to set the display mode of SIM 22-4 trouble history when a same
trouble occurred repeatedly. There are two display modes: display as one
trouble and display as several series of troubles.
trouble occurred repeatedly. There are two display modes: display as one
trouble and display as several series of troubles.
Setting
38
Used to set whether printing is continued or stopped when the developer life
is expired or when the fusing wed ends.
is expired or when the fusing wed ends.
Setting
41
Used to set Enable/Disable of the magnification ratio automatic select
function (AMS) in the center binding mode.
function (AMS) in the center binding mode.
Setting
49
Used to set the copy speed mode of postcards.
Setting
50
Used to set Enable/Disable of the black and white highlight function and the
2-color/Single display function.
2-color/Single display function.
Setting
52
Used to set whether non-print paper (insertion paper, cover, etc.) is counted
or not.
or not.
Setting
53
Used to set YES/NO of the auto color calibration.
Setting
54
Used to set the printer calibration YES/NO.
Setting
65
Used to set the finisher alarm mode.
Setting
67
Used to set the summer time timing and the time zone.
Setting
69
Used to set the display of spare toner preparation and near end when the
toner quantity reaches 25%.
toner quantity reaches 25%.
Setting
27
1
Used to set non-detection of communication error (U7-00) with RIC
Setting
2
Used to set the FSS function (sender registration number, host server
telephone number).
telephone number).
Setting
4
Used to set the FSS function (initial, call, toner order automatic send).
Setting
5
Used to set the machine tag No. (This function allows the host computer to
check the machine tag No.)
check the machine tag No.)
Setting
Communication (RIC/
MODEM)
MODEM)
6
Used to set the FSS function (manual service call).
Setting
7
Used to set the FSS function (enable, alert call).
Setting
9
Paper transport time between sensors / Gain adjustment retry number
setting
setting
Setting
10
Used to clear the history information of trouble prediction
Data clear
11
Used to check the serial communication retry number history and the
scanner gain adjustment retry number history.
scanner gain adjustment retry number history.
Other
12
Used to check the error history of high density, half tone process control,
and automatic registration adjustment.
and automatic registration adjustment.
Other
13
Used to check the history of paper transport time between sensors.
Other
14
Used to set the FSS function connection mode. (Only "Disable
→ Enable" is
allowed.)
Setting
30
1
Used to check the operations of the sensors and the detectors in other than
the paper feed section and the control circuits.
the paper feed section and the control circuits.
Operation test/Check
2
Used to check the operations of the sensors and the detectors in the paper
feed section and the control circuits.
feed section and the control circuits.
Operation test/Check
33
1
Used to check the operations of the card reader sensor and the control
circuit.
circuit.
Operation test/Check
40
2
Manual paper feed tray paper width detector detection level adjustment
Adjustment/Setting
Paper feed
7
Used to adjust the manual paper feed tray width detection level.
Adjustment/Setting
Paper feed
12
Used to perform the tray 3 paper width detection level adjustment.
Adjustment/Setting
Paper feed
41
1
Used to check the operations of the document size sensor and the control
circuit.
circuit.
Operation test/Check
2
Used to adjust the document size sensor detection level.
Adjustment
3
Used to check the operations of the document size sensor and the control
circuit.
circuit.
Operation test/Check
43
1
Used to set the fusing temperature in each mode.
Setting
4
Used to perform the fusing temperature setup 2 in each operation mode.
(Continued from SIM 43-1.)
(Continued from SIM 43-1.)
Setting
20
Used to set the environmental correction under low temperature and low
humidity (L/L) for the fusing temperature setting in each mode (SIM 43-1).
humidity (L/L) for the fusing temperature setting in each mode (SIM 43-1).
Adjustment/Setting
21
Used to set the environment correction under high temperature and high
humidity (H/H) for the fusing temperature setting (SIM 43-1) in each paper
mode.
humidity (H/H) for the fusing temperature setting (SIM 43-1) in each paper
mode.
Adjustment/Setting
22
Used to set the environment correction under low temperature and low
humidity (L/L) for the fusing temperature setting (SIM 43-4) in each paper
mode.
humidity (L/L) for the fusing temperature setting (SIM 43-4) in each paper
mode.
Adjustment/Setting
23
Used to set the environment correction under high temperature and high
humidity (H/H) for the fusing temperature setting (SIM 43-4) in each paper
mode.
humidity (H/H) for the fusing temperature setting (SIM 43-4) in each paper
mode.
Adjustment/Setting
24
Used to set the correction of the temperature adjustment value of SIM 43-1
and 43-4.
and 43-4.
Adjustment/Setting
31
Used to check the operation of the fusing web cleaning motor and the
control circuit.
control circuit.
Operation test/Check
32
Used to set the compulsory operation of fusing web cleaning at job end.
Adjustment/Setting
Main
Sub
Function (Purpose)
Purpose
Section
Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man46) service manuals if exist.