MX-5500N, MX-6200N, MX-7000N (serv.man46). Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual online

MX-7000N  SIMULATION  7 – 4
22
1
Used to check the print count value in each section and operation mode. 
(Used to check the maintenance timing.)
Adjustment/Setting/Operation data 
output/Check
2
Used to check the total numbers of misfeed and troubles. (When the number 
of total jam is considerably great, it is judged as necessary for repair.)
Adjustment/Setting/Operation data 
check
3
Used to check the misfeed positions and the number of misfeed at each 
position.
* The trouble position can be troubleshooted according to this data.
Adjustment/Setting/Operation data 
check
4
Used to check the trouble (self diag) history.
Adjustment/Setting/Operation data 
check
5
Used to check the ROM version of each unit (section).
Other
6
Used to output the list of the setting and adjustment data (simulations, FAX 
soft switch, counters).
Adjustment/Setting/Operation data 
check
8
Used to check the counter value of the finisher, the DSPF, and the scan 
(reading).
Adjustment/Setting/Operation data 
check
9
Used to check the number of use (print quantity) of each paper feed section. 
Adjustment/Setting/Operation data 
check
Paper feed, ADU, LCC
10
Used to check the system configuration (option, internal hardware).
Adjustment/Setting/Operation data 
check
11
Used to check the use frequency of FAX (send/receive). (Only when FAX is 
installed.)
Adjustment/Setting/Operation data 
check
FAX
12
Used to check the misfeed position in the DSPF and the number of misfeed 
of each position. (If the number of misfeed is considerably great, it may lead 
to the decision for repair.)
Adjustment/Setting/Operation data 
check
DSPF
13
Used to check the running time of the process section. (OPC drum, DV unit, 
toner bottle).
Adjustment/Setting/Operation data 
check
19
Used to check each counter value related the network scanner. 
Adjustment/Setting/Operation data 
check
90
Used to output the list of various set data.
Adjustment/Setting/Operation data 
check
23
2
Used to check the trouble history of paper jam and misfeed. (If the number of 
misfeed and troubles is considerably great, it may be judged as necessary to 
repair.)
Adjustment/Setting/Operation data 
check
80
Used to check the operations of the sensors and detectors in the paper feed 
and transport section.
Operation test/Check
Paper feed, transport
24
1
Used to clear the jam counter, and the trouble counter. (The counters are 
cleared after completion of maintenance.)
Data clear
2
Used to clear the number of use (the number of prints) of each paper feed 
section.
Data clear
3
Used to clear the counter value of the finisher, the DSPF, and scan 
(reading).
Data clear
4
The maintenance counter and the print counters of the transfer unit and the 
fusing unit are cleared. (After completion of maintenance, the counters are 
cleared.)
Data clear
5
Used to clear the developer counter. (After replacement of developer, this 
counter is cleared.)
Data clear
6
Used to clear the copy counter value.
Data clear
7
Used to clear the OPC drum counter value. (After replacement of the OPC 
drum, this counter is cleared.)
Data clear
9
Used to clear the printer mode print counter and the self print mode print 
counter. 
Data clear
10
Used to clear the FAX counter value. (Only when FAX is installed.)
Data clear
15
Used to clear various counters in the scan mode related to image send. 
Data clear
30
Used to initialize the administrator password.
Data clear
31
Used to initialize the service mode password.
Data clear
25
1
Used to check the operations of the developing section.
Operation test/Check
Process (Developing 
section)
2
Used to make the initial setting of the toner density when replacing 
developer. (Automatic adjustment)
Setting
Process (Photoconductor/
Developing/Transfer/
Cleaning)
26
2
Used to set the paper size of the large capacity tray (LCC). (When the paper 
size is changed, this simulation must be executed to change the paper size 
in software.)
Setting
Paper feed
3
Used to set the auditor setting mode. (Setting must be made according to 
the auditor use conditions.)
Setting
Auditor
5
Used to set the count mode of the total counter and the maintenance 
counter.
Setting
6
Used to set the specifications according to the destination. (Paper, fixed 
magnification ratios, etc.)
Setting
10
Used to set the trial mode of the network scanner.
Setting
18
Used to set Disable/Enable of the toner save mode operation. (For the 
Japan and the UK versions.)
Setting
30
Used to set the operation mode corresponding to the CE mark (Europe 
safety standards). (For slow start to drive the fusing heater lamp)
Setting
Main
Sub
Function (Purpose)
Purpose
Section
Page of 127
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man46) service manuals if exist.