AR-NC3D (serv.man2). Instructions for upgrading AR-NC3D firmware using the FTP Download Utility - Sharp Copying Equipment Handy Guide. Page 6

Read Sharp AR-NC3D (serv.man2) Handy Guide online

Failure Recovery
If the Write-to-Flash starts but does not complete, DO NOT RESET THE NIC OR POWER
CYCLE THE PRINTER. The NUP is still in RAM and allows a reconnection and another attempt
to download. Please follow the failure recovery procedure below.
Failure Recovery Procedure:
1.  Escape (Ctrl C) from the FTP DL
2.  Using a standard FTP client program, perform the Manual Update Procedure described
Note: If the NIC is reset, the NUP in RAM is lost. If the Flash has been corrupted, the unit will
only restart in IPX download mode. The IPX Flash-up Utility must then be used to load
the unit Flash memory.
Download Flash Update Code and write to Flash memory
The Flash Update Code must be downloaded into RAM. The NIC Update Program then writes
that code into NIC Flash memory.
Procedure
1.  Execute FTP using the device IP address, “update” as the username and “update” as the
password.
2.  Switch to binary mode using the FTP “BIN” command. The UPD file must be transferred
to NIC RAM in binary mode.
3.  Using the FTP “PUT” command, transfer the appropriate UPD file (example:
OTExxx.UPD) to the NIC.
4.  When UPD file transfer is complete, the NIC will reset and execute the new code in Flash
on restart.
5.  Break the FTP connection (you may need to use Ctrl C).