AR-C260 FLASH UPGRADE PROCEDURE
Engine Procedure (Tiger)
1.
Power off the copier and remove the Tiger control PWB. Set the control
jumpers as follows:-
jumpers as follows:-
AR-Mxxx -
Set JP2 & JP5 to H
AR-Pxxx
Set JP2 & JP4 to H
ARP350/450 Version
PRN-Control PWB
Function
Jumper switching function
The mark printed on PWB
SET
Default Setting
BOOT program start
DIAG
JP4
ON
OFF
Flash write (Control-PWB)
VCCW
JP2
H/off enable
L/On
protect
ARM350/450 Version
MFP-Control PWB
Function
Jumper switching function
The mark printed on PWB SET Default setting
BOOT program start
DIAG
JP5
ON
OFF
Flash write (Control-PWB)
VCCW
JP2
H/Off
enable
L/On
protect
2.
Remove the flashcard from the AR-C260 and insert into the write socket on the Tiger
control pwb. Re-install the Control PWB back into the machine.