Read Sharp AR-C260 (serv.man37) FAQ online
AR-C260 FLASH UPGRADE PROCEDURE
3.
Connect the Level Converter Serial I/F cable(s) to both ICU Main PWB and the Computer
Serial Port (COM1).
Serial Port (COM1).
4. Start
Windows.
Within the “Windows” device manager, double click the “Communications Port” to be
used and under “Port setup”, check the communication speed is set to
115200 bits/sec.
used and under “Port setup”, check the communication speed is set to
115200 bits/sec.
5.
Turn on the copier. Within the Copier LCD, enter Simulation 49-02 and set the
communication speed (baud rate) to 115200bps. (The set value of the Copier
communication speed must be the same value as the Computer).
communication speed (baud rate) to 115200bps. (The set value of the Copier
communication speed must be the same value as the Computer).
6.
Enter Simulation 49-01 and press “Execute”
7.
Start the Maintenance program on the PC side (Double click “Mainte_xxx.exe” File).
8.
Select the communication speed (baud rate) on the option menu. Set the value to the
same as entered within Simulation 49-02 on the Copier.
same as entered within Simulation 49-02 on the Copier.
Cont’d