AR-C260 (serv.man37). Firmware Upgrade Procedure. - Sharp Copying Equipment FAQ (repair manual). Page 3

Read Sharp AR-C260 (serv.man37) FAQ online

 
AR-C260 FLASH UPGRADE PROCEDURE
 
 
9. 
Double click “Simulation Command List”, “Special (Whale)” and then “Download to the 
Program Area”. 
 
 
 
 
10. 
Select the ROM type (PWB name) to be written and click “Start”. 
 
 
 
 
11. 
Select the ROM Data file and click “Open”. 
 
 
 
 
 
Downloading (writing to the Flash ROM) is now started. 
 
12. 
When “The Program was complete” is displayed on the AR-C260 LCD screen, power off 
the copier and remove the Flash ROM from the writing socket. 
 
Firmware Upgrade is complete. 
 