AR-C260 FLASH UPGRADE PROCEDURE
 
 
The following table identifies the flash ROM’s used in the AR-C260(M). 
 
Flash ROM type 
Capacity 
Part Number 
ICU  Flash ROM 
32Mbit x 2 
VHi28F322L22F 
 
 
 
PCU Flash ROM 
8Mbit 
VHi28F081L07F 
 
 
 
OPE Flash ROM 
16Mbit x 2 
VHi28F162L01F 
 
 
 
MFP (Scanner) Flash ROM 
16Mbit 
VHi28F161L01F 
 
Note: Do not use Cougar or Bear type flashcards in the AR-C260 
 
Flash upgrades may be required at the following times: 
 
1)  In order to improve the performance 
2)  When installing a new spare Flash ROM to the machine for repair 
3)  When the program in the Flash ROM has been corrupted 
 
There are Three methods of upgrading the firmware on the AR-C260 copier:- 
 
a) 
Removing the flash cards from the AR-C260 and upgrading them on the Tiger 
series machines by using “FCOPY”. 
 
b) 
By connecting a computer to the ICU PWB, the program data of the Flash Rom  
Is written from the computer to the Flash ROM by utilising a Level Converter. 
 
c) 
The two flash ROM sockets on the ICU Main PWB can be used to copy the 
program (Source ROM) to another Flash ROM. In this method, the Source ROM 
can be created by downloading the “SRC” program file to a “2 x 32Mbit” flashcard, 
utilising the Level Converter. 
 
Engine Procedure (Level Converter) 
 
1. 
Power off the copier and remove the paper tray cabinet & shield plate. 
 
 
 
 
 
 
 
 
 
 
 
2. 
Insert the Flash ROM that requires upgrading into the write socket of the ICU Main PWB  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 
 
AR-C260 FLASH UPGRADE PROCEDURE
 
 
3. 
Connect the Level Converter Serial I/F cable(s) to both ICU Main PWB and the Computer 
Serial Port (COM1). 
 
4. Start 
Windows. 
Within the “Windows” device manager, double click the “Communications Port” to be 
used and under “Port setup”, check the communication speed is set to 
115200 bits/sec. 
 
5. 
Turn on the copier. Within the Copier LCD, enter Simulation 49-02 and set the 
communication speed (baud rate) to 115200bps. (The set value of the Copier 
communication speed must be the same value as the Computer). 
 
 
 
6. 
Enter Simulation 49-01 and press “Execute” 
 
 
 
7. 
Start the Maintenance program on the PC side (Double click “Mainte_xxx.exe” File). 
 
 
 
8. 
Select the communication speed (baud rate) on the option menu. Set the value to the 
same as entered within Simulation 49-02 on the Copier. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 
 
AR-C260 FLASH UPGRADE PROCEDURE
 
 
9. 
Double click “Simulation Command List”, “Special (Whale)” and then “Download to the 
Program Area”. 
 
 
 
 
10. 
Select the ROM type (PWB name) to be written and click “Start”. 
 
 
 
 
11. 
Select the ROM Data file and click “Open”. 
 
 
 
 
 
Downloading (writing to the Flash ROM) is now started. 
 
12. 
When “The Program was complete” is displayed on the AR-C260 LCD screen, power off 
the copier and remove the Flash ROM from the writing socket. 
 
Firmware Upgrade is complete. 
 
 
AR-C260 FLASH UPGRADE PROCEDURE
 
 
Engine Procedure (Tiger) 
 
1. 
Power off the copier and remove the Tiger control PWB. Set the control  
jumpers as follows:- 
 
 
 
 
AR-Mxxx  - 
Set JP2 & JP5 to H 
 
 
 
 
AR-Pxxx 
Set JP2 & JP4 to H 
 
ARP350/450 Version 
PRN-Control PWB 
Function 
Jumper switching function 
The mark printed on PWB 
SET 
Default Setting 
BOOT program start 
DIAG 
JP4 
ON 
 
OFF 
 
Flash write (Control-PWB) 
VCCW 
JP2 
H/off enable
L/On 
protect 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
ARM350/450 Version 
MFP-Control PWB 
Function 
Jumper switching function 
The mark printed on PWB  SET               Default setting 
BOOT program start 
DIAG 
JP5 
ON 
 
OFF 
Flash write (Control-PWB) 
VCCW 
JP2 
H/Off
enable 
L/On 
protect
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2. 
Remove the flashcard from the AR-C260 and insert into the write socket on the Tiger 
control pwb. Re-install the Control PWB back into the machine. 
 
 
Note: The write socket on the Tiger control board is the only spare socket 
Available 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 
JP4
 
JP7
 
JP5
 
JP2
JP3
JP6
JP6
 
JP2
JP3
JP4
JP5
Page of 8
Display

Download Sharp AR-C260 (serv.man37) FAQ

Here you can read online and download Sharp AR-C260 (serv.man37) FAQ in PDF. AR-C260 (serv.man37) faq will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AR-C260 (serv.man37) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.