AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 SIMULATION - 2
C. Simulation operation and procedure basic pattern
The pattern numbers in the table below are specified to the detailed procedures described below (for each simulation). Refer to them as necessary.
No.
Simulation operation and 
procedure pattern
Screen type
Operations and procedures common to every pattern
1
Used to set the 
adjustment only.
Adjustment value 
input menu
Enter the adjustment value with the 10-key and press the [OK] key.
If the input value is within the set range, it is stored. If it is outside the set range, it is not 
set. 
2
Used to select the mode 
and set the adjustment 
value.
Mode selection menu
Select the mode with the 10-key and press the [OK] key, and the menu shifts to the 
adjustment value input menu.
Adjustment value 
input menu
Enter the adjustment value with the 10-key and press the [OK] key.
If the input value is within the set range, it is stored. If it is outside the set range, it is not 
set. 
Pressing the [BACK] key returns to the mode selection menu.
3
Used to set the 
adjustment value and 
output.
Adjustment value 
input menu
Enter the adjustment value with the 10-key and press the [OK] key, and the menu goes 
to the execution display.
If the input value is within the set range, it is stored. If it is outside the set range, it is not 
set. 
Execution menu
During execution, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the adjustment value 
input menu.
4
Used to select the mode 
and set the adjustment 
value and make an 
output.
Mode selection menu
Select the mode with the 10-key and press the [OK] key, and the menu shifts to the 
adjustment value input menu.
Adjustment value 
input menu
Enter the adjustment value with the 10-key and press the [OK] key, and the menu goes 
to the execution display.
If the input value is within the set range, it is stored. If it is outside the set range, it is not 
set. 
Pressing the [BACK] key returns to the mode selection menu.
Execution menu
During execution, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the adjustment value 
input menu.
5
1 sheet print mode
Mode selection menu
Enter the adjustment value with the 10-key and press [
] key to shift to the next  mode, 
and press [
] key to shift to the previous mode. Press the [START] key to make 1 sheet 
print.
Pressing the [OK] key shifts to the adjustment value input menu.
If the input value is within the set range, it is stored. If it is outside the set range, it is not 
set. 
Adjustment value 
input menu
Press the adjustment value with the 10-key and press the [START] key to make 1 sheet 
print.
After completion of print, the mode selection screen appears.
6
Used to clear.
Initial menu
Pressing the [OK] key shifts to the confirmation display.
Confirmation menu
The confirmation message is displayed. Press the [OK] key to clear.
Pressing the [BACK] key returns to the initial menu without cleaning.
7
Used to select the item to 
clear and execute 
clearing.
Selection menu
Select the counter to clear with the 10-key and press the [OK] key, and the menu goes to 
the confirmation display.
Confirmation menu
The confirmation message is displayed. Press the [OK] key to clear.
Pressing the [BACK] key returns to the selection menu without cleaning.
8
Used to operate loads.
Initial menu
Pressing the [OK] key shifts to the execution display.
Execution menu
During execution of load operation, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the initial menu.
9
Used to select the load to 
operate and operate the 
load.
Selection menu
The names of the loads which can be operated are displayed. Select one with the 10-key 
and press the [OK] key, and the menu will go to the execution menu. 
Execution menu
During execution of load operation, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the mode selection 
menu.
10
Used to set the number of 
times, the magnification 
ratio, and the original 
size, and check the 
operations.
(Scanner unit)
Input menu of the 
number of times
Select the mode with the 10-key and press the [OK] key, and the menu shifts to the 
magnification ratio and original size setup menu.
Magnification ratio 
and original size 
setup menu
Select the magnification ratio with [
][
] keys. (Fixed magnification ratio)
Set the magnification ratio to a desired level with [
][
] keys. (1% increment)
Select the original size with the [PAPER SIZE] key.
Pressing the [OK] key shifts to the execution display.
Pressing the [BACK] key returns to the input menu of the number of times.
Execution menu
The scanner unit is moved at the speed corresponding to the set magnification ratio and 
the original size.
During execution, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the setup menu of the 
magnification ratio and the original size.
Page of 58