AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 58

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 TROUBLE CODE LIST - 9
CE
01
Content
The print server card (AR-NC3D) is not 
installed or defective.
Detail
NC3D connection failure
Cause
NC-3D is not installed to the AR-PB2A 
board.
NC-3D control PWB trouble
Check 
and 
remedy
1) Check  that  the  NC-3D  is  installed  to
the AR-PB2A board.
2) Output the NIC Config. Page to check
the NIC version.
3) Replace the NIC.
02
Content
The specified mail server or the FTP 
server is not found.
Detail
The specified mail server or the FTP 
server is not found.
Cause
Network Cable connection failure
Network setup failure
SMTP server/FTP server/NST trouble
Check 
and 
remedy
1) Check that the Network Cable is 
inserted properly.
2) Check that the connected network 
supports TCP/IP protocol.
3) Check from the Web Page that the 
Primary/Secondary E-mail Server 
Address or the Destination FTP server/
Desktop PC address are properly set.
4) If the above address is described with 
Hostname, check that the DNS server 
is properly set.
5) Check that the SMTP server/FTP 
server/NST causes a trouble or not.
03
Content
The specified server does not correspond 
during image transmission.
Detail
The specified server does not correspond 
during image transmission.
Cause
Network Cable connection failure
SMTP server/FTP server/NST trouble
Check 
and 
remedy
1) Check that the Network Cable is 
inserted properly.
2) Check that the SMTP server/FTP 
server/NST causes a trouble or not.
04
Content
The entered account name of the FTP 
server or the password is invalid.
Detail
The entered account name of the FTP 
server or the password is invalid.
Cause
Network Cable connection failure
The account name of the FTP server 
recorded as the destination or the 
password for the account name is 
erroneous.
Check 
and 
remedy
1) Check that the Network Cable is 
inserted properly.
2) Check that the account name of the 
FTP server recorded as the destination 
and the password for the account 
name are proper.
Trouble 
code
Details of trouble
Main 
code
Sub 
code
CE
05
Content
The entered directory of the FTP server is 
invalid.
Detail
The entered directory of the FTP server is 
invalid.
Cause
Network Cable connection failure
Check that the directory name exists in the 
FTP server recorded as the destination.
Check 
and 
remedy
1) Check that the Network Cable is 
inserted properly.
2) Check that the directory name exists in 
the FTP server recorded as the 
destination.
EE
EL
Content
Developer adjustment trouble (Over-toner 
abnormality)
Details
An abnormality occurred in execution of 
automatic developer adjustment.
Sample data over-toner was detected.
Cause
Toner concentration sensor abnormality
Toner concentration trouble
Developing unit trouble
MCU PWB failure
Check 
and 
remedy
Use SIM 25-2 to perform the auto 
developer adjustment.
EU
Content
Developer adjustment trouble (Under-
toner abnormality)
Details
An abnormality occurred in execution of 
automatic developer adjustment.
Sample data under-toner was detected.
Cause
Toner concentration sensor abnormality
Toner concentration trouble
Developing unit trouble
MCU PWB failure
Check 
and 
remedy
Use SIM 25-2 to perform the auto 
developer adjustment.
PF
00
Content
RIC copy inhibit signal received
Details
The copy inhibit command from RIC is 
received. 
Cause
Judged by the host. 
Check 
and 
remedy
Information the host. 
Trouble 
code
Details of trouble
Main 
code
Sub 
code
Page of 58
Display

Download Sharp AR-235 (serv.man9) Service Manual (Repair Manual)