AR-235/275 ADJUSTMENTS - 7
<Adjustment specification>
La = Lb, Lc = Ld
5) After completion of adjustment, manually turn the mirror base drive
pulley, scan the mirror base A and mirror base B fully, and check
that the mirror bases are not in contact with each other.
If the mirror base rail is moved extremely, the mirror base may be in
contact with the frame or the original glass. Be careful to avoid this.
(10) Main scanning direction (FR direction) magnification 
ratio adjustment (SIM 48-1)
 Before  performing  this  adjustment,  be  sure  to  check  that  the
CCD unit is properly installed.
1) Put a scale on the original table as shown below.
2) Execute SIM 48-1.
3) After  warm-up,  shading is  performed  and the current set  value of
the main scanning direction magnification ratio is displayed on the
display section in 2 digits.
4) Select the mode and press the start key again.
5) Auto correction mode (SIM48-1-1)
The  mirror  unit  moves  to  the  shading  position,  and  the  reference
width  of  the  reference  white  plate  is  scanned,  and  the  correction
value is automatically calculated from that scanned value.
The correction value is displayed and a copy is made.
6) Compare the scale image and the actual scale.
If  a  fine  adjustment  is  required,  switch  to  the  manual  correction
mode  with  the  magnification  ratio  display  key  and  perform  fine
adjustment.
7) Manual correction mode (SIM48-1-2)
Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
 A judgement must be made with 200mm width, and must not be
made with 100mm width.
• Error in the auto correction mode
(11) Sub scanning direction (scanning direction) 
magnification ratio adjustment  (SIM 48-1-3)
a. OC mode in copying
Note: Execute the procedure after completion of SIM 48-1-3.
1) Put a scale on the original table as shown below, and make a nor-
mal (100%) copy.
2) Compare the scale image and the actual scale.
If necessary, perform the following adjustment procedures.
3) Execute SIM 48-1-3.
4) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
b. RSPF sub scanning direction magnification ratio
Note: Before  performing  this  adjustment,  be  sure  to  check  that  the
CCD  unit  is  properly  installed  and  that  OC  mode  adjustment  in
copying has been completed.
1) Put a scale on the original table as shown below, and make a nor-
mal (100%) copy to make a test chart.
 Since the printed copy is used as a test chart, put the scale in
paralled with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy.
3) Compare the scale image and the actual image.
If necessary, perform the following adjustment procedures.
4) Execute SIM 48-1-4.
5) After warm-up, shading is performed.
The current front surface sub scanning direction magnification ratio
correction value is displayed in two digits on the display section.
• When La > Lb
Shift the mirror base B rail upward by the half of the difference of
La–Lb.
• When La < Lb
Shift the mirror base B rail downward by the half of the difference
of Lb–La.
Example: When La = 12mm and Lb = 9mm, shift the mirror base
B rail upward by 1.5mm.
• When 
.E >.F
Shift the mirror base B rail downward by the half of the difference
of Lc–Ld.
• When Lc < Ld
When  Lc  <  Ld,  move  the  mirror  base  B  on  the  paper  feed  side
upward.
When  moving  the  mirror  base  rail,  hold  the  mirror  base  rail  with
your hand.
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Main scanning 
direction 
magnification 
ratio
At normal: 
±1.0%
48-1
Add 1: 0.1% 
increase
Reduce 1: 0.1% 
decrease
1 – 99
Display
Content
Major cause
Copy quantity 
display "– –"
The correction 
value 
calculated is 
over 5%.
• Improper  position  of  reference
width line of the reference white
plate
• Improper installation of CCD unit
Paper jam 
lamp ON
Reference line 
scanning error
• Defective CCD
• No reference white plate
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Sub scanning 
direction 
magnification 
ratio (OC mode)
At normal: 
±1.0%
48-1-
3
Add 1: 
0.05% increase
Reduce 1: 
0.05% decrease
1 – 99
Page of 58