AR-235/275 ADJUSTMENTS - 8
6) Enter the set value and press the start key.
The set value is stored and a copy is made.
7) Execute SIM 48-1-5.
The  current  back  surface  sub  scanning  direction  magnification
ratio is displayed in two digits on the display section.
8) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
(12) Off center adjustment (SPF mode)
 Before  performing  this  adjustment,  be  sure  to  check  that  the
paper off center is properly adjusted.
1) Place  the  center  position  adjustment  test  chart  (sheet  with  a
straight line in the scan direction at the center) on the SPF.
2) Make a normal copy from the manual paper feed tray, and check
the printed copy with the test chart.
If any adjustment is required, perform the following procedure. 
3) Execute SIM 50-12.
4) After  warm-up,  shading is  performed  and the current set  value of
the  off  center  adjustment  is  displayed  on  the  display  section  in  2
digits.
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
(13) OC (SPF) open/close detection position adjustment
1) Execute SIM 41-3.
2) Gradually close the OC (SPF) from the full open position, and mea-
sure distance A when the display on the operation panel changes.
(See the figure below.)
Distance A = Table glass top - OC (SPF) handle rib
<Adjustment specification>
OC (SPF) open/close position A: 125 – 225mm
3) If the distance is outside the specified range, adjust the open/close
sensor attachment plate position as shown below.
(14) Original sensor adjustment (SIM 41-2, 41-4)
1) Set A3 (11" x 17") paper on the OC table.
(Keep the SPF (OC cover) open.)
2) Execute SIM 41-2.
3) Keep A=125mm, and execute SIM 41-4. (Do not put paper on the
table.)
4) Check the reaction with SIM 41-1. 
(15) SPF white correction pixel position adjustment 
(required in an SPF model when replacing the lens 
unit) (SIM63-7)
1) Fully open the SPF.
2) Execute SIM 63-7.
3) When the operation panel displays "COMPLETE," the adjustment
is completed.
4) If  the  operation  panel  displays  "ERROR,"  perform  the  following
measures.
• When the display is 0:
Check that the SPF is open.
Check that the lamp is ON. (If the lamp is OFF, check the MCU con-
nector.)
Check that the CCD harness is properly inserted into the MCU con-
nector.
• When the display is 281 or above:
1) Remove the table glass.
2) Remove the dark box.
3) Slide the  lens unit toward the front side and attach it, then exe-
cute SIM.
• When the display is 143 or below:
1) Remove the table glass.
2) Remove the dark box.
3) Slide  the  lens  unit  toward  the  rear  side  and  attach  it,  then  exe-
cute SIM.
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Sub scanning 
direction 
magnification 
ratio (SPF mode)
At normal: 
±1.0%
48-1-4
48-1-5
Add 1: 
0.05% increase
Reduce 1: 
0.05% decrease
1 – 99
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Original off 
center mode 
(SPF mode)
Single: Center 
± 3.0mm
50-12
Add 1: 0.1mm 
shift to R side
1 – 99
Duplex: Center 
±3.5mm
Reduce 1: 0.1mm 
shift to L side
A
 Distance <  : Shift toward A.
 Distance >  : Shift toward B.
A
B
R
F
Page of 58
Display