Read Sharp AR-235 (serv.man9) Service Manual online
AR-235/275 SIMULATION - 6
Operation/procedure
The status of sensors and detectors in the scanner section is dis-
played. The active sensors and detectors are highlighted.
played. The active sensors and detectors are highlighted.
Operation/procedure (Pattern 11)
Set a document on the APF paper feed tray, and fix it with tape.
Enter the number, set the magnification ratio and the original size and
press the [OK] key, and the SPF unit will operate in a speed corre-
sponding to the setup.
press the [OK] key, and the SPF unit will operate in a speed corre-
sponding to the setup.
The magnification ratio can be selected in the range of 50% – 200% in
9 steps with
9 steps with
↑
↓
keys.
(AB series) 50
→
70
→
81
→
86
→
100
→
115
→
122
→
141
→
200
(Inch series) 50
→
64
→
77
→
95
→
100
→
121
→
129
→
141
→
200
The scan counter is displayed during execution.
Note: Executable only when the SPF/RSPF is installed.
Operation/procedure
The operations of sensors and detectors in the SPFsection are dis-
played.
played.
The active sensors and detectors are highlighted.
Note: Executable only when the SPF/RSPF is installed.
Operation/procedure (Pattern 9)
The names of the loads which can be operated are displayed. Select
the load to be checked with the 10-key.
the load to be checked with the 10-key.
The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
(20 times)
(20 times)
Note: Executable only when the SPF/RSPF is installed.
Operation/procedure
Used to display the operations of sensors and detectors in the finisher
section.
section.
The active sensors and detectors are highlighted.
Magnification ratio
25% to 400%
Default
100%
Document size
Varies depending on the destination.
Set number of times1 to 999 (0: Continuous
operation)
1-2
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of sensor and detector in
the scanning (read) section and the related circuit.
the scanning (read) section and the related circuit.
Section
Optical (Image scanning)
Item
Operation
MHPS
Mirror home position sensor
2
2-1
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of the SPF unit and the
related circuit.
related circuit.
Section
SPF
Item
Operation
(Initial screen)
(Input/Selection screen) (Executing screen)
Magnification ratio
50% to 200%
Default
100%
Document size
Varies depending on the destination.
Single/duplex
Selectable only when RSPF is installed, fixed
(single) for SPF.
(single) for SPF.
Set number of times1 to 999 (0: Continuous
operation)
2-2
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of sensors and detectors
in the SPF unit and the related circuit.
in the SPF unit and the related circuit.
Section
SPF
Item
Operation
Sim1-2 SENSOR CHECK
MHPS
Sim2-1 SPF AGING
115% A3
1SIDE
100%
2SIDE
86%
ZOOM <100%>
0
Sim2-1 SPF AGING
115% A3
1SIDE
100%
2SIDE
86%
ZOOM <100%> EXEC
Sim2-1 SPF AGING
115% A3
1SIDE
100%
2SIDE
86%
ZOOM <100%>
EXEC
EMPS
Empty sensor
DLS1
Tray length sensor (small)
DLS2
Tray length sensor (large)
DWS1
Tray width sensor (small)
DWS2
Tray width sensor (middle)
DWS3
Tray width sensor (large)
FGOD
Paper feed cover sensor
DFD
Document entry detection sensor
RDD
Document exit sensor
OPCLS
Book sensor
2-3
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of the loads in the SPF
unit and the control circuits.
unit and the control circuits.
Section
SPF
Item
Operation
(Initial screen)
(Executing screen)
1:DTM-F
SPF motor forward rotation
2:DTM-R
SPF motor reverse rotation
3:DFSOL
SPF document pick-up solenoid
4:CLH
SPF document exit transport clutch
5:GSOL
RSPF document exit gate solenoid
6:RSOL
RSPF document pressure solenoid
3
3-2
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of sensor and detector in
the finisher and the related circuit.
the finisher and the related circuit.
Section
Sorter/Finisher
Item
Operation
Sim2-2 SENSOR CHECK
EMPS
DLS1 DLS2
DWS1 DWS2 DWS3
FGOD
DFD RDD
OPCLS
Sim2-3 OUTPUT CHECK
1:DTM-F 4:CLH
2:DTM-R 5:GSOL
3:DFSOL 6:RSOL
EXEC
2
Sim2-3 OUTPUT CHECK
1:DTM-F 4:CLH
2:
DTM-R
5:GSOL
3:DFSOL 6:RSOL
EXEC
2
Sim3-2 SENSOR 1/2
INPD FWPS
JGHP1
JGHP2 JGPD T1OD
T1PF
PGOP
T2OD
OFHP T2UP
T2DN
Click on the first or last page to see other AR-235 (serv.man9) service manuals if exist.