UP-X300 (serv.man50). Updated 7 7 - Sharp EPOS FAQ (repair manual). Page 26

Read Sharp UP-X300 (serv.man50) FAQ online

be applied to the last item when pressing the % key. If the item is not set to 
the relationship “No Association” will appear. Therefore you can enable or 
inhibit individual items to be given a manual item discount. You can have upto 
20 relationships (20 individual PLU or Dept or Group)  
 
4.38 PLU Halo.
 
Q. I would like to set a maximum price for my open priced PLU? I.e. £9.99 
A. To do this set the maximum price / HALO amount for the PLU. 
Pos Programming – Products – PLU – select the PLU that you require and 
ensure the following are set within the Price tab. 
Standard price = 0 
Entry Type = Open & Preset 
HALO= 9.99 
 
Within Pos Programming – Employee – Employee Function – Limitation 
Halo/Lalo = Disallowed 
 
4.39 PLU Halo / Open priced PLU entry.
 
Q. How can I stop my Open & Preset Priced PLU from repeating the previous 
price, when it is pressed? 
A. To do this create a Macro as follows, example for PLU 1   
 


PLU0001 
 
4.40 PLU Price Levels or Price Bands (Time Zone).
 
Q. How do I set up Price Bands for my PLU items and then use them? 
A. You need to allocate the MENU# key to the keyboard (under SCREEN) 
then Create Time Zones (1 to 5) under POSProgramming-System settings-
RevenueCentre-Time Zone, to use the feature press the level number 
followed by the MENU# key (this can be put under macro control)   
 
4.41 Void Mode and Manager Voids not printing in Z sales reports.
 
Q. Is it possible to prevent the Void mode transactions and Manager Voids 
from appearing in the Z1/Z2 and Z3 sales reports? 
A. Yes, there is a setting in: 
POSProgramming/System Settings/Administration/System Settings: “Printing 
of Void/MGR Voids” YES/NO 
 
4.42 Group Discounts 
 
Q. Is it possible to set up a discount rate that can be applied only to the food 
items within a transaction? 
A. Yes, you could use the Group Discount feature this, would allow the server 
to enter the different items than after ST press the GRP Disc# and the 
discount will only apply to the PLU or Dept’s that have been set to this group. 
 
4.43 Area/Room default by Terminal 
 
Page of 38