127 
17.5.10 
Indoor Backup Heater OLP Abnormality (H70) 
Malfunction Decision Conditions: 
During operation of indoor backup heater, when no power supplies to indoor backup heater or OLP open circuit. 
 
Malfunction Caused: 
1  Faulty power supply connector connection. 
2  Faulty connector connection. 
3  Faulty indoor backup heater overload protector (OLP). 
4  Faulty indoor unit PCB (main). 
 
Abnormality Judgment: 
Continue for 60 seconds. 
 
 