17.5.6  Compressor Low Pressure Protection (H42) 
Malfunction Decision Conditions: 
During operation of heating and after 5 minutes compressor ON, when outdoor pipe temperature below -29°C or 
above 26°C is detected by the outdoor pipe temperature sensor. 
 
Malfunction Caused: 
1  Dust accumulation on the outdoor unit heat exchanger. 
2  Air short circuit at outdoor unit. 
3  2 way valve partially closed. 
4  Faulty outdoor unit fan motor. 
5  Refrigerant shortage (refrigerant leakage). 
6  Clogged expansion valve or strainer. 
7  Faulty outdoor pipe temperature sensor. 
8  Faulty outdoor unit main PCB (main). 
 
 