17.5.8  Outdoor High Pressure Abnormality (H64) 
Malfunction Decision Conditions: 
During operation of cooling and heating, when the outdoor high pressure sensor output signal is 0 Vdc or 5 Vdc. 
 
Malfunction Caused: 
1  Faulty connector connection. 
2  Faulty sensor. 
3  Faulty outdoor unit PCB (main). 
 
Abnormality Judgment: 
Continue 4 times in 20 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 