17.5 Self-diagnosis 
Method 
17.5.1  Connection Capability Rank Abnormality (H12) 
Malfunction Decision Conditions: 
During startup operation of cooling and heating, the capability rank of indoor checked by the outdoor is used to 
determine connection capability rank abnormality. 
 
Malfunction Caused: 
1  Wrong model interconnected. 
2  Wrong indoor unit or outdoor unit PCB (main) used. 
3  Faulty indoor unit or outdoor unit PCB (main). 
 
Abnormality Judgment: 