SUB 140P - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL SUB 140P EMC - CB Certificate online

 
 
 
 
Page 10 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
Soldered terminations not used  as protective 
mechanism 
 
N/A 
11.2.1 
Measurement of temperature rises 
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts 
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table 11.2) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 
2 cm² 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
N/A 
 
Class I protective earthing maintained 
Class II apparatus 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 
N/A 
11.2.5 
Temperature rise of windings 
(see appended table 11.2) 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table 11.2) 
 
12 
MECHANICAL STRENGTH 
 
12.1.1 
Bump test where mass > 7 kg 
Measured: 10.1 Kg 
12.1.2 
Vibration test 
 
12.1.3 
Impact hammer test 
 
 
Steel ball test 
 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Measured: 10.1 Kg 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
N/A 
12.2 
Fixing of knobs, push buttons, keys and levers 
No such device 
N/A 
12.3 
Remote controls with hazardous live parts 
No remote control device with 
hazardous live parts 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawer is provided 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial socket is 
provided as isolation 
N/A 
Page of 87
Display