Read JBL SUB 140P EMC - CB Certificate online
Page 10 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Soldered terminations not used as protective
mechanism
mechanism
N/A
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
Class II apparatus
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N/A
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table 11.2)
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass > 7 kg
Measured: 10.1 Kg
P
12.1.2
Vibration test
P
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Measured: 10.1 Kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
No such device
N/A
12.3
Remote controls with hazardous live parts
No remote control device with
hazardous live parts
hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawer is provided
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided as isolation
provided as isolation
N/A