SUB 140P - JBL Audio EMC - CB Certificate (repair manual). Page 7

Read JBL SUB 140P EMC - CB Certificate online

 
 
 
 
Page 7 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) 
................................................................................. : 
Primary wires: min. 0.4 mm for 
each layer 
Bobbin of Transformer (DT1, 
NT1670NL) between 
primary/secondary winding and 
core: 1.0 mm 
Bobbin of Transformer (T1, 
NT1759NL) between 
primary/secondary winding and 
core: 0.71 mm 
Bobbin of Transformer (T2, 
F02801610 and NT1810NL) 
between primary/secondary 
winding and core: 1.0 mm 
 
Reinforced insulation > 0,4 mm (mm)  ................... :  Optocoupler (U2) > 0.4 mm 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
3 layers tape of transformer 
(DT1, NT1670NL; T2, 
F02801610 and NT1810NL) 
between primary winding and 
secondary winding (RI) 
Triple insulation wire of 
transformer (T1, NT1759NL) 
between primary winding and 
secondary winding (RI) 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 
N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
For Transformer (DT1, 
NT1670NL; T2, F02801610 
and NT1810NL) only 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Measured min. 0.4 mm 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
Measured min. 0.4 mm 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts.                
Double insulation between internal hazardous live 
parts and conductors connected to accessible 
parts 
 
8.11 
Detaching of wires 
 
Page of 87
Display