Page 7 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
8.8
Basic or supplementary insulation > 0,4 mm (mm)
................................................................................. :
Primary wires: min. 0.4 mm for
each layer
each layer
Bobbin of Transformer (DT1,
NT1670NL) between
primary/secondary winding and
core: 1.0 mm
NT1670NL) between
primary/secondary winding and
core: 1.0 mm
Bobbin of Transformer (T1,
NT1759NL) between
primary/secondary winding and
core: 0.71 mm
NT1759NL) between
primary/secondary winding and
core: 0.71 mm
Bobbin of Transformer (T2,
F02801610 and NT1810NL)
between primary/secondary
winding and core: 1.0 mm
F02801610 and NT1810NL)
between primary/secondary
winding and core: 1.0 mm
P
Reinforced insulation > 0,4 mm (mm) ................... : Optocoupler (U2) > 0.4 mm
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
3 layers tape of transformer
(DT1, NT1670NL; T2,
F02801610 and NT1810NL)
between primary winding and
secondary winding (RI)
(DT1, NT1670NL; T2,
F02801610 and NT1810NL)
between primary winding and
secondary winding (RI)
Triple insulation wire of
transformer (T1, NT1759NL)
between primary winding and
secondary winding (RI)
transformer (T1, NT1759NL)
between primary winding and
secondary winding (RI)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
For Transformer (DT1,
NT1670NL; T2, F02801610
and NT1810NL) only
NT1670NL; T2, F02801610
and NT1810NL) only
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Measured min. 0.4 mm
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Measured min. 0.4 mm
P
8.10
Double insulation between conductors connected
to the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts
to the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts
P
8.11
Detaching of wires