Read JBL SUB 140P EMC - CB Certificate online
Page 12 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Note:
clearance cl and creepage
distance dcr at/of:
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
On PCB solder side:
L – N before fuse link (BI)
326
230
2.0
5.0
2.5
5.0
Between two end of fuse link
(BI)
(BI)
326
230
2.0
2.1
2.5
5.1
Optocopuler between primary
and secondary (RI)
and secondary (RI)
326
230
4.0
5.4
4.6
5.4
Primary component and
secondary component (CY4)
(RI)
secondary component (CY4)
(RI)
326
230
4.0
5.1
4.6
5.1
Transformer between primary
and secondary (RI)(DT1)
and secondary (RI)(DT1)
368
230
4.0
5.6
4.6
5.6
Transformer between primary
and secondary (RI)(T1)
and secondary (RI)(T1)
472
230
4.5
6.6
4.6
6.6
Transformer between primary
and secondary (RI)(T2)
and secondary (RI)(T2)
408
230
4.0
7.7
4.6
7.7
On PCB component side:
L – N before fuse link (BI)
326
230
2.0
5.0
2.5
5.0
Between two end of fuse link
(BI)
(BI)
326
230
2.0
3.7
2.5
6.7
Optocopuler between primary
and secondary (RI)
and secondary (RI)
326
230
4.0
7.7
4.6
7.7
Primary component and
secondary component (CY4)
(RI)
secondary component (CY4)
(RI)
326
230
4.0
8.3
4.6
8.3
Transformer between primary
and secondary (RI)(DT1)
and secondary (RI)(DT1)
368
230
4.0
10.5
4.6
10.5
Transformer between primary
and secondary (RI)(T1)
and secondary (RI)(T1)
472
230
4.5
14
4.6
14
Transformer between primary
and secondary (RI)(T2)
and secondary (RI)(T2)
408
230
4.0
18.5
4.6
18.5
Switch transformer: (DT1)
Primary winding to core (RI)
368
230
4.0
2)
10.6
5.0
2)
10.5
Switch transformer: (T1)
Primary winding to core (BI)
472
230
2.0
3)
3
2.5
3)
3
Secondary winding to core
(SI)
(SI)
472
230
2.0
3)
3
2.5
3)
3
Click on the first or last page to see other SUB 140P service manuals if exist.