SUB 140P - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL SUB 140P EMC - CB Certificate online

 
 
 
 
Page 12 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
Note:  
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
 (V) 
required cl 
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
On PCB solder side: 
L – N before fuse link (BI) 
326 
230 
2.0 
5.0 
2.5 
5.0 
Between two end of fuse link 
(BI) 
326 
230 
2.0 
2.1 
2.5 
5.1 
Optocopuler between primary 
and secondary (RI) 
326 
230 
4.0 
5.4 
4.6 
5.4 
Primary component and 
secondary component (CY4) 
(RI) 
326 
230 
4.0 
5.1 
4.6 
5.1 
Transformer between primary 
and secondary (RI)(DT1) 
368 
230 
4.0 
5.6 
4.6 
5.6 
Transformer between primary 
and secondary (RI)(T1) 
472 
230 
4.5 
6.6 
4.6 
6.6 
Transformer between primary 
and secondary (RI)(T2) 
408 
230 
4.0 
7.7 
4.6 
7.7 
On PCB component side: 
L – N before fuse link (BI) 
326 
230 
2.0 
5.0 
2.5 
5.0 
Between two end of fuse link 
(BI) 
326 
230 
2.0 
3.7 
2.5 
6.7 
Optocopuler between primary 
and secondary (RI) 
326 
230 
4.0 
7.7 
4.6 
7.7 
Primary component and 
secondary component (CY4) 
(RI) 
326 
230 
4.0 
8.3 
4.6 
8.3 
Transformer between primary 
and secondary (RI)(DT1) 
368 
230 
4.0 
10.5 
4.6 
10.5 
Transformer between primary 
and secondary (RI)(T1) 
472 
230 
4.5 
14 
4.6 
14 
Transformer between primary 
and secondary (RI)(T2) 
408 
230 
4.0 
18.5 
4.6 
18.5 
Switch transformer: (DT1) 
Primary winding to core (RI) 
368 
230 
4.0
2)
 
10.6 
5.0
2)
 
10.5 
Switch transformer: (T1) 
Primary winding to core (BI) 
472 
230 
2.0
3)
 
2.5
3)
 
Secondary winding to core 
(SI) 
472 
230 
2.0
3)
 
2.5
3)
 
Page of 87