SUB 140P - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL SUB 140P EMC - CB Certificate online

 
 
 
 
Page 9 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 
9.1.5 
Pre-set controls tested with 2,5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No such component 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
Measured: 0 Vpeak 
 
If C is not greater than 0,1 
µ
F no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
N/A 
 
30 mm diameter test tool for 5 s (100 or 250 N)  ... :  250N 
9.2 
No hazard after removing a cover by hand 
No such part 
N/A 
 
10 
INSULATION REQUIREMENTS 
 
10.1 
Insulation resistance (M
) at least 2 M
 min. after 
surge test for basic and 4 M
 min. for reinforced 
insulation ................................................................. : 
The surage test, insulation 
resistance test and dielectric 
strength test have performed 
between L/N and accessible 
part 
10.2 
Humidity treatment 48 h or 120 h  .......................... :  48 h 
10.3 
Insulation resistance and dielectric strength 
(see appended table 10.3) 
 
Insulation resistance and dielectric strength 
across BASIC or SUPPLEMENTARY insulation 
(Class I) 
 
N/A 
 
Insulation resistance and dielectric strength 
across REINFORCE insulation (Class II) 
 
 
11 
FAULT CONDITIONS 
 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
No softening solder 
N/A 
 
Flames extinguish within 10 seconds 
 
N/A 
Page of 87