TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2,5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No such component
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Measured: 0 Vpeak
P
If C is not greater than 0,1
µ
F no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
N/A
30 mm diameter test tool for 5 s (100 or 250 N) ... : 250N
P
9.2
No hazard after removing a cover by hand
No such part
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (M
Ω
) at least 2 M
Ω
min. after
surge test for basic and 4 M
Ω
min. for reinforced
insulation ................................................................. :
The surage test, insulation
resistance test and dielectric
strength test have performed
between L/N and accessible
part
resistance test and dielectric
strength test have performed
between L/N and accessible
part
P
10.2
Humidity treatment 48 h or 120 h .......................... : 48 h
P
10.3
Insulation resistance and dielectric strength
(see appended table 10.3)
P
Insulation resistance and dielectric strength
across BASIC or SUPPLEMENTARY insulation
(Class I)
across BASIC or SUPPLEMENTARY insulation
(Class I)
N/A
Insulation resistance and dielectric strength
across REINFORCE insulation (Class II)
across REINFORCE insulation (Class II)
P
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
No softening solder
N/A
Flames extinguish within 10 seconds
N/A