Page 8 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All primary wires are fixed by
double secure method
double secure method
P
Vibration test carried out ........................................ : Comply with sub-clause 12.1.2
P
8.12
This clause is void
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No such device
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
N/A
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Appliance inlet is used
P
All-pole switch or circuit breaker with >3 mm
contact separation
contact separation
No such device
N/A
8.19.2
Mains switch ON indication
A lighted display during the
“ON” position is clearly
discernible and the word
“Power” is marked on the
mains switch
“ON” position is clearly
discernible and the word
“Power” is marked on the
mains switch
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
No such component
N/A
8.22
Non-separable thin sheet material
No such material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such voltage
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
Measured max. open circuit
voltage: 328 Vpeak
voltage: 328 Vpeak
U1: max. 0.328 Vpeak
U2: max. 0.276 Vpeak
P
Discharge not exceeding 45
µ
C
35.78
µ
C
P
Energy of discharge not exceeding 350 mJ
< 15 KV
N/A
9.1.1.2
Test with test finger and test probe
P