Read JBL SUB 140P EMC - CB Certificate online
Page 6 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings are covered by
lacquer
lacquer
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No such components are
replaced by hand
replaced by hand
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No such hazardous live parts
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No such construction
N/A
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Class II apparatus
N/A
A resistor bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
A capacitor bridging basic insulation complying
with 14.2.1 a)
with 14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformer (CT1, T1, DT1
and T2) complied with 14.3
and T2) complied with 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
X-capacitor (CX1, CX2) and Y-
capacitor (CY1, CY2) are
provided
capacitor (CY1, CY2) are
provided
P
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
Y-capacitor (CY3, CY4) is
provided
provided
P
8.7
This clause is void
N/A