Read JBL SUB 140P EMC - CB Certificate online
Page 2 of 75
TP10110019-ST
TRF No.: IECEN60065G
Test item particulars
Classification of installation and use ......................... : Class II
Supply connection .................................................... : Appliance inlet is provided
Possible test case verdicts
Test case does not apply to the test object ................ : N/A (Not Applicable)
Test item does meet the requirement ......................... : P (Pass)
Test item does not meet the requirement ................... : F (Fail)
Testing
Date of receipt of test item ........................................... : November 09, 2010
Date(s) of performance of test ..................................... : November 11, 2010 – January 17, 2011
General remarks
The test results presented in this report relate only to the item(s) tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
“(see Appendix #)” refers to additional information appended to the report.
"(see appended table #)" refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first
be approved in writing by Intertek. The observations and test results in this report are relevant only to the
sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first
be approved in writing by Intertek. The observations and test results in this report are relevant only to the
sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.
When determining the test conclusion, the Measurement Uncertainty of test has been considered.
Summary of testing and conclusions
The sample(s) tested complies with the requirements of IEC 60065: 2001 + A1: 2005 + A2: 2010 and EN
60065: 2002 + A1: 2006 + A11: 2008.
60065: 2002 + A1: 2006 + A11: 2008.
Compliance with the National requirements of “(countries)” as given in CB Bulletin “(113A)” was also
confirmed.
General information
These products covered by this report are Subwoofer for indoor use. There are considered as a portable and
Class II apparatus.
Factory information:
Dongguan Meiloon Acoustic Equipments Co., Ltd.
Feng Huang Gang Ind. Estate, No. 77, Yuan Lin Road, Tangxia, Dongguan, Guangdong, 523727 China
Class II apparatus.
Factory information:
Dongguan Meiloon Acoustic Equipments Co., Ltd.
Feng Huang Gang Ind. Estate, No. 77, Yuan Lin Road, Tangxia, Dongguan, Guangdong, 523727 China
Click on the first or last page to see other SUB 140P service manuals if exist.