TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Switching Transformer (DT1)
Primary winding and core:
Reinforce insulation.(core is
consider as secondary)
Primary winding and core:
Reinforce insulation.(core is
consider as secondary)
Switching Transformer (T1,
T2) Primary winding and core:
Reinforce insulation.(core is
consider as primary)
T2) Primary winding and core:
Reinforce insulation.(core is
consider as primary)
P
Coil formers and partition walls > 0,4 mm
Measured 0.71 mm minimum
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high-voltage component
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Between two ends of fuse link:
2.1 mm
2.1 mm
P
14.5.1.1
a) Thermal cut-outs separately approved
No such device
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such device
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : 4AL 250V for SUB140P
2.5AL 250V for SUB140P/230
P
14.5.2.3
Not possible to connect fuses in parallel ............... : Single fuse is used
P