SUB 140P - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL SUB 140P EMC - CB Certificate online

 
 
 
 
Page 16 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Switching Transformer (DT1) 
Primary winding and core: 
Reinforce insulation.(core is 
consider as secondary) 
Switching Transformer (T1, 
T2) Primary winding and core: 
Reinforce insulation.(core is 
consider as primary) 
 
Coil formers and partition walls > 0,4 mm 
Measured 0.71 mm minimum 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
N/A 
14.4 
High voltage components 
 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No high-voltage component 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 
Protective devices 
 
 
Protective devices used within their ratings 
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Between two ends of fuse link: 
2.1 mm 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such device 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such device 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... :  4AL 250V for SUB140P 
2.5AL 250V for SUB140P/230 
14.5.2.3 
Not possible to connect fuses in parallel  ............... :  Single fuse is used  
Page of 87
Display