Read JBL SB 200 (serv.man3) EMC - CB Certificate online
Page 65 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
14.5.2.2
Add the following sentence before the last
paragraph.
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
paragraph.
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
N/A
14.5.3
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
14.5.4
Replace IEC 60127 by “IEC 60127 or JIS C 6575”.
N/A
14.6.1
Add the following paragraph after NOTE.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
or d.c.
- the voltage across the open switch contacts
exceeds 35 Vpeak ac or 24 Vdc.
N/A
14.6.1
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.6.2
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.6.3
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.6.5
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.7
Replace IEC 60950 by JIS C 6950:2006.
N/A
Click on the first or last page to see other SB 200 (serv.man3) service manuals if exist.