SB 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 60

Read JBL SB 200 (serv.man3) EMC - CB Certificate online

Page 60 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Rated current or power consumption  .....................:
 
Pass 
 
Measured consumption at 240 V, 50Hz not 
exceeding the marked value by more than 10% 
 Pass 
HEATING UNDER NORMAL CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values 
(Table 3 – Normal Conditions) 
For tropical climates; permissible temperatures 
shall be reduced with 10K 
The values of the temperature rises are based on a 
maximum ambient temperature of 45
°C for tropical 
climates 
 Pass 
10 INSULATION 
REQUIREMENTS 
 
10.2 Humidity 
treatment 
For tropical conditions; 120 hours, 90-95% RH, 
40
±2°C 
 Pass 
10.3 
Insulation resistance and dielectric strength 
 
Pass 
11 FAULT 
CONDITIONS 
 
11.2 
Heating under fault conditions 
Temperature rises not exceeding specified values 
(Table 3 – Fault conditions) 
For tropical climates; permissible temperatures 
shall be reduced with 10K 
 
 Pass 
 
 
Ukrainian deviation for 6th ED (GOST 12.2.006-87, 2007-05-29) 
1. 
"National difference" in testing of conformity with the 
requirements of IEC 60335 series standards is the 
value of the nominal voltage that is fixed 220V а.с. 
for the power supply network in Ukraine and is used 
for testing instead of the value specified bу the 
manufacturer. 
 N/A 
 
Page of 78