SB 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 69

Read JBL SB 200 (serv.man3) EMC - CB Certificate online

Page 69 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
National Differences – Japan,  J60065 (H23) 
16.1 
Add the following paragraph after the third 
paragraph. 
An external earth wire of Class 0I equipment shall 
be green/yellow, and the length of external earth 
wire of plug with an external earth wire shall be 
equal or more than 10 cm from the plug. 
 N/A 
16.2 
Replace the first paragraph by the following. 
Power supply cord conductors complied with JIS C 
3662 (corresponding to IEC 60227) or JIS C 3663 
(corresponding to IEC 60245) shall have a nominal 
cross-sectional area not less than those shown in 
table 18. If power supply cord conductors comply 
with other standards, it shall comply with relevant 
wiring requirements. 
See appended table CL.14.
Pass 
16.2 
Replace Table 18 by the following. 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-
sectional area 
 
mm
2
 
up to and including 6 
Over 6 up to and including 10
Over 10 up to and including 
16 
0,75 
1,5 
a
 The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from the 
socket-outlets providing MAINS power for other 
apparatus. 
 
See appended table CL.14.
Pass 
16.3 
In item a), replace IEC 60885-1 by JIS C 3661-
1:1998. 
 N/A 
 
In item b), replace IEC 60227-2 by JIS C 3662-2 
(corresponding to IEC 60227-2). 
 N/A 
16.5 
Add “or CLASS 0I EQUIPMENT used a plug with 
an external earth wire” after the words, CLASS I 
EQUIPMENT. 
 N/A 
20.1 
In Note 3, replace each IEC 60065 and IEC 60707 
by “JIS C 6065” and “JIS C 0066:2001 (IEC 
60707). 
 N/A 
Annex B 
Replace normative by Informative. 
 
N/A 
Annex G 
Replace IEC 60707 by JIS C 0066:2001 
Replace IEC 60695-2-2 by JIS C 60695-2-2:2000.
Replace IEC 60695-11-10 by JIS Z 2391:1999. 
 Pass 
Annex N 
Add “- protective earthing lead wire, protective 
earthing contact of appliance inlet or external 
protective earthing terminal in case of Class 0I 
apparatus.” after the second dash of N.1.3. 
 N/A 