SB 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 64

Read JBL SB 200 (serv.man3) EMC - CB Certificate online

Page 64 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
National Differences – Japan,  J60065 (H23) 
10.3.2 
In Table 5, add the following values to the sub-
table of NOTE. 
 
Test voltage (peak) 
Operating 
Voltage (peak) 
Curve A 
Curve B 
142 V 
1 414 V 
2 828 V 
 
See appended table 
CL.10.3. 
Pass 
11.2.1 
Add the following after the original NOTE. 
NOTE 2  Fuses except for the ones according to 
IEC 60127 shall be tested in consideration of the 
characteristic. 
See appended table 
CL.11.2. 
Pass 
11.2.3 
Add “and CLASS 0I” after the words, CLASS I. 
 
N/A 
13.4 
In NOTE 2 of Table 11, replace IEC 60664-1 by 
JIS C 0664:2003 (corresponding to IEC 60664-1). 
See appended table 
CL.11.2. 
Pass 
14.3.3.2 
In the second sentence of the first paragraph, add 
“or JIS C 2107, JIS C 2336 and JIS C 2338” after 
the reference, IEC 60454. 
 N/A 
14.5.1.1 
In item a), add “JIS C 9730 series or” before the 
reference, IEC 60730 series. 
 N/A 
14.5.1.2 
In the first sentence of item a), replace “IEC 
60691” by “IEC 60691, JIS C 6691:2003 or 
Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material”. 
 N/A 
14.5.1.2 
After the second sentence of item a), replace “IEC 
60691” by “JIS C 6691:2003 or IEC 60691”. 
 N/A 
14.5.2.1 
Replace the first and the second sentence as 
follows: 
Fuse-links, DIRECTLY CONNECTED TO THE 
MAINS, used in order to prevent the apparatus 
from becoming unsafe within the sense of this 
standard shall comply with 
- the relevant part of IEC 60127 or JIS C 6575, 
unless they have a rated current outside the range 
specified in that standard. In the latter case, they 
shall comply with the relevant part of IEC 60127 or 
JIS C 6575 as far as applicable, or 
- Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material (limited to Fuses with the 
rated current of 1 A or more). 
See appended table CL.14.
Pass 