Page 64 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
10.3.2
In Table 5, add the following values to the sub-
table of NOTE.
table of NOTE.
Test voltage (peak)
Operating
Voltage U (peak)
Curve A
Curve B
142 V
1 414 V
2 828 V
See appended table
CL.10.3.
CL.10.3.
Pass
11.2.1
Add the following after the original NOTE.
NOTE 2 Fuses except for the ones according to
IEC 60127 shall be tested in consideration of the
characteristic.
NOTE 2 Fuses except for the ones according to
IEC 60127 shall be tested in consideration of the
characteristic.
See appended table
CL.11.2.
CL.11.2.
Pass
11.2.3
Add “and CLASS 0I” after the words, CLASS I.
N/A
13.4
In NOTE 2 of Table 11, replace IEC 60664-1 by
JIS C 0664:2003 (corresponding to IEC 60664-1).
JIS C 0664:2003 (corresponding to IEC 60664-1).
See appended table
CL.11.2.
CL.11.2.
Pass
14.3.3.2
In the second sentence of the first paragraph, add
“or JIS C 2107, JIS C 2336 and JIS C 2338” after
the reference, IEC 60454.
“or JIS C 2107, JIS C 2336 and JIS C 2338” after
the reference, IEC 60454.
N/A
14.5.1.1
In item a), add “JIS C 9730 series or” before the
reference, IEC 60730 series.
reference, IEC 60730 series.
N/A
14.5.1.2
In the first sentence of item a), replace “IEC
60691” by “IEC 60691, JIS C 6691:2003 or
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material”.
60691” by “IEC 60691, JIS C 6691:2003 or
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material”.
N/A
14.5.1.2
After the second sentence of item a), replace “IEC
60691” by “JIS C 6691:2003 or IEC 60691”.
60691” by “JIS C 6691:2003 or IEC 60691”.
N/A
14.5.2.1
Replace the first and the second sentence as
follows:
Fuse-links, DIRECTLY CONNECTED TO THE
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
- the relevant part of IEC 60127 or JIS C 6575,
unless they have a rated current outside the range
specified in that standard. In the latter case, they
shall comply with the relevant part of IEC 60127 or
JIS C 6575 as far as applicable, or
- Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material (limited to Fuses with the
rated current of 1 A or more).
follows:
Fuse-links, DIRECTLY CONNECTED TO THE
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
- the relevant part of IEC 60127 or JIS C 6575,
unless they have a rated current outside the range
specified in that standard. In the latter case, they
shall comply with the relevant part of IEC 60127 or
JIS C 6575 as far as applicable, or
- Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material (limited to Fuses with the
rated current of 1 A or more).
See appended table CL.14.
Pass