SB 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 63

Read JBL SB 200 (serv.man3) EMC - CB Certificate online

Page 63 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
National Differences – Japan,  J60065 (H23) 
7.1.5 
Add the following paragraph as 2
nd
paragraph of 
Condition “d “in Table 3. 
For materials which are not listed in Table 3, 
temperature rises in the normal operating 
conditions are considered satisfactory if these 
materials comply with item 3 of detailed 
regulations, 1.(1),b, Appendix 4 in the Ministerial 
Ordinance on stipulating technical requirements for 
the Electrical Appliance and Material. Permissible 
temperature rise of “Supply cords and wiring 
insulation” is applicable only to the materials used 
in supply cords complying with JIS C 3662 
(corresponding to IEC 60227) or JIS C 3663 
(corresponding to IEC 60245). Materials used in 
other wiring shall comply with item 3 of detailed 
regulations, 1.(1).b, Appendix 4 in the Ministerial 
Ordinance on stipulating technical requirements for 
the Electrical Appliance and Material. 
 Pass 
7.1.5 
In the first paragraph of Condition “f” of Table 3, 
add ”JIS K 7206:1999 or” before the reference, 
ISO 306. 
 Pass 
7.1.5 
In Condition “f,” 1) of Table 3, add ”JIS K 
7206:1999 or” before the reference, ISO 306. 
 Pass 
7.2 
In NOTE 2, add “or JIS standard (identical to or 
modified IEC)” after the word, IEC standard. 
 N/A 
8.5 
In the first paragraph, add “and Class 0I 
Equipment” after the words, Class I Equipment. 
 N/A 
8.5 
In the six paragraph (before NOTE 3), add the 
following to the end of the first sentence. 
CLASS 0I EQUIPMENT shall be provided with a 
protective earthing terminal at any point outside 
the apparatus where easily visible or a protective 
external earth wire from mains plug. 
 N/A 
8.11 
In NOTE 2, c), add “or JIS C 2107, JIS C 2336, JIS 
C 2338” after the reference, IEC 60454. 
 N/A 
9.1.1.1 
In the last paragraph, add the following sentence 
after the first sentence. 
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 mA.
 N/A 
10 
In NOTE, replace “IEC 60664-1 and IEC 60664-4 
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4 [8]”
 Pass 
10.1 
Add “CLASS 0I EQUIPMENT and” to the head of 
the first paragraph. 
 N/A 
Page of 78
Display