Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
15.1.1
Replace the paragraph before NOTE 3 by the
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
N/A
15.1.1
Replace NOTE 4 by the following.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
N/A
15.1.2
Delete the following sentence in NOTE.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
N/A
15.1.3
Replace the references, “IEC 60083 [1], IEC
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
N/A
15.2
Add “and CLASS 0I EQUIPMENT” after the words,
“CLASS I EQUIPMENT”
“CLASS I EQUIPMENT”
N/A
15.2
Add the following paragraphs after the first
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
N/A
15.2
Delete the following paragraph.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits
shall not be connected to the protective earthing
conductor.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits
shall not be connected to the protective earthing
conductor.
N/A
15.3.1
In the first paragraph, replace IEC 60998-2-2 by
“IEC 60998-2-2 or JIS C 2814-2-2:2001”.
“IEC 60998-2-2 or JIS C 2814-2-2:2001”.
N/A
15.3.1
In the first paragraph, replace IEC 60999 by IEC
60999-1.
60999-1.
N/A
15.3.1
In the third paragraph, replace IEC 60335-1 by JIS
C 9335-1:2003 (corresponding to IEC 60335-1).
C 9335-1:2003 (corresponding to IEC 60335-1).
N/A
15.3.3
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-3:2001”.
2:2001 or JIS B 0205-3:2001”.
N/A
15.3.5
In the second paragraph, replace IEC 60950 by
JIS C 6950:2006.
JIS C 6950:2006.
N/A