Read JBL SB 200 (serv.man3) EMC - CB Certificate online
Page 66 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
15.1.1
Replace the first and second paragraph by the
following.
Plugs and appliance couplers for the connection of
the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
relevant JIS standards for plugs, socket-outlets,
appliance couplers or interconnection couplers. If
there is no appropriate JIS standard, they shall
comply with the relevant IEC standards.
Appliance connectors, interconnection outlets and
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material are accepted. In that case,
if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with dimensions
and ratings specified in the relevant standard
sheets of IEC 60320-1.
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
following.
Plugs and appliance couplers for the connection of
the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
relevant JIS standards for plugs, socket-outlets,
appliance couplers or interconnection couplers. If
there is no appropriate JIS standard, they shall
comply with the relevant IEC standards.
Appliance connectors, interconnection outlets and
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material are accepted. In that case,
if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with dimensions
and ratings specified in the relevant standard
sheets of IEC 60320-1.
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60884) of the
Ordinance.
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60884) of the
Ordinance.
- Appliance couplers: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60320-1) of the
Ordinance.
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60320-1) of the
Ordinance.
- Appliance inlets: IEC 60320-1
- Interconnection outlets: Appendix 4 of Article 1 of
- Interconnection outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. IEC
60320-2-2.
requirements for the Electrical Appliance. IEC
60320-2-2.
- Interconnection couplers: Appendix 4 of Article 1
of the Ministerial Ordinance on stipulating
technical requirements for the Electrical
Appliance.
technical requirements for the Electrical
Appliance.
Delete NOTE 1 and NOTE 2.
See appended table CL.14.
Pass
15.1.1
Replace the paragraph after NOTE 2 by the
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS 0I and CLASS II
apparatus shall not permit connection of CLASS I
apparatus.
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS 0I and CLASS II
apparatus shall not permit connection of CLASS I
apparatus.
N/A
Click on the first or last page to see other SB 200 (serv.man3) service manuals if exist.