- Page 10 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
(The approved Class II switching power supply be used)
P
9.1
Testing on the outside
N
9.1.1
For voltage > 1000 V ac or > 1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage.
N
9.1.1.1
Touch current measured from terminal devices
using the network in Annex D ................................ :
using the network in Annex D ................................ :
N
Discharge not exceeding 45
μC
N
Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
N
9.1.2
No hazardous live shafts of knobs, handlers or
levers
levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe 16 of IEC 61 032
pin (10 N); test probe 16 of IEC 61 032
N
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61 032
straight wire (1 N); test probe D of IEC 61 032
N
9.1.5
Pre-set controls tested with 2 mm x 100 mm test
pin (10 N); test probe C of IEC 61 032
pin (10 N); test probe C of IEC 61 032
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N
If C is not greater than 0,1
μF no test needed
N
9.1.7
Enclosure sufficiently resistant to external force
N
Test probe 11 of IEC 61 032 for 10 s (50 N)
N
Test hook of fig. 4 for 10 s (20 N)
N
30 mm diameter test tool for 5 s (100 or 250 N) .... :
N
9.2
No hazard after removing a cover by hand
N
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (M
Ω) at least 2 MΩ min. after
surge test for basic and 4 M
Ω min. for reinforced
insulation
:
The approved Class II
switching power supply be
used.
switching power supply be
used.
P
10.2
Humidity treatment 48 h or 120 h :
At 93% R.H., 48h, 30
°C.
P