ON TIME MICRO (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online

 
- Page 14 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
Table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
 N 
 
Shielded by a barrier to FV 0 or metal ................... :  
14.3 
Inductors and windings 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ............................... :
 N 
 
Transformers and inductors separately approved . :  
14.3.2 General 
 
 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 N 
14.3.3.2 
Transformers meet the constructional 
requirements 
 
N 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
 N 
 
Coil formers and partition walls 
≥ 0,4 mm 
 N 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
 N 
 
Coil formers and partition walls 
≥ 0,4 mm 
 N 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N 
Page of 39