Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 9 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
N
8.11
Detaching of wires
N
No undue reduction of creepage or clearance
distances if wires become detached
distances if wires become detached
N
Vibration
test carried out ........................................ :
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (pull test 50 N, for
10 s)
10 s)
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
N
8.16
Only special supply equipment can be used
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
8.19.1 Disconnection
device
N
All-pole switch or circuit breaker with > 3mm
contact separation
contact separation
N
8.19.2
Mains switch ON indication
N
8.20
Switch not fitted in the mains cord
N
8.21
Bridging components comply with clause 14
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.