Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 7 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Ionizing radiation under fault condition
N
6.2
Laser radiation, emission limits to IEC 60 825-1 ... :
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table).
P
7.1.1
Temperature rise of accessible parts
(see appended table).
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table).
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table).
P
7.1.4
Temperature rise of windings
(see appended table).
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table).
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
°C
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK (The approved Class II switching power
supply be used)
AGAINST ELECTRIC SHOCK (The approved Class II switching power
supply be used)
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such part.
N
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Approved switching power
supply be used.
supply be used.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used.
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No hand removable cover.
N
8.5
Class I equipment
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N